AVGPC 2U 24-Bay 2x Xeon 4310 128GB DDR4 1TB NVME 2x 8TB SSD
- 128 GB
- 1 TB
We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
Dual-voltage power supply delivers 12 VDC or 24 VDC at 6 A from 115/230 VAC input in a steel enclosure measuring 15.5 in high, 12.00 in wide and 4.50 in deep, and meets UL 294.
The Altronix AL600ULXD is a dual-voltage power supply and charger delivering 12 VDC or 24 VDC at 6 A. It accepts 115 VAC or 230 VAC input at 60 Hz and mounts in a steel enclosure with a grey finish measuring 15.5 in high, 12.00 in wide and 4.50 in deep. The unit carries UL294, UL1481 and CUL listings and ships with battery leads and a cam lock.
This unit suits security and access-control installers who need a single power supply that can be set to either 12 VDC or 24 VDC for different devices on the same job. It is not for buyers who require a fixed single-voltage supply, higher current output, or an input frequency other than 60 Hz.
The deciding specification is the 6 A output current available at either 12 VDC or 24 VDC. Confirm that the connected load does not exceed this rating before selecting the AL600ULXD.
Measured against everything we stock in Rack & Tower Servers, at today’s prices. Recalculated every night.
New to this? Buying server hardware with crypto — what to check, what it costs to pay, and what is never asked for.
| Product | |
|---|---|
| Product type | Other |
Secure the steel enclosure using its 12.00 in width and 15.5 in height mounting points, connect 115VAC or 230VAC input, then attach the included battery leads to the charger terminals — skipping the battery leads leaves the backup function inactive.
Inspect the battery leads and connected backup batteries every six months; replace batteries when they no longer hold a full charge, and verify the cam lock remains tight on the gray steel enclosure.
The 6 A output current limit at either 12 VDC or 24 VDC is reached first; the supply will not exceed this rating regardless of 115 VAC or 230 VAC input.
More in Rack & Tower Servers
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?