Anvil 0500421037 Riser Clamp 1 In 9 3/8 In 120 Lb
A riser clamp supports and steadies 1-inch copper tube risers, insulated or not, with a 120 lb maximum load and copper-plated steel construction
- Product typeDrain Components
- Supports copper tube risers with 120 lb capacity
- Copper-plated steel construction resists corrosion
- Meets A-A-1192A Type 8 standard
- Complies with ANSI/MSS SP-69 and MSS SP-58
- Bolt size 3/8 in for secure fastening
Anvil Riser Clamp 1 In 9 3/8 In
This Anvil riser clamp is built from carbon steel with copper plating to support and steady 1-inch copper tube risers. It handles a maximum load of 120 lb across a length of 9 3/8 inches using a 3/8-inch bolt. The clamp fits both insulated and non-insulated tubing for plumbing installations.
Suited For Plumbers Securing Vertical Copper Risers
Plumbers securing vertical copper risers in residential or commercial systems will find this clamp matches the required tube size and load rating. It is not intended for use with hanger rods, so installers needing rod-suspended supports should look at different hardware. The design addresses steadying rather than hanging applications.
Meets A-A-1192A Type 8 And MSS SP-69 Standards
The single specification that decides fit is compliance with A-A-1192A Type 8, WW-H-171-E Type 8, ANSI/MSS SP-69 and MSS SP-58 Type 8. These standards govern dimensions, material and load performance for riser clamps in copper piping systems. Verifying that your project requires Type 8 compliance confirms this is the correct part.
How it compares
Measured against everything we stock in Drain Stoppers, Strainers & Traps, at today’s prices. Recalculated every night.
- Price $8.99
- Cheaper than about 86% of the 4,240 comparable items (median $31.99).
Specifications
| Product | |
|---|---|
| Brand name | Anvil |
| Model name | 0500421037 |
| Product type | Drain Components |
Questions about this item
How much weight can the 0500421037 riser clamp support before it reaches its load limit?
The clamp is rated for a maximum load of 120 Lb, which is the limit that applies during sustained use.
Does the copper-plated steel construction affect heat transfer or noise when the clamp secures a hot water riser all day?
The carbon steel body with copper plating conducts heat from the pipe but adds no moving parts, so it generates no noise during continuous operation.
What size bolts are required to install this riser clamp on a 1-inch tube?
The clamp uses 3/8 In bolts, which are included with the assembly for direct installation.
More in Drain Stoppers, Strainers & Traps





