Anvil 0500421086 Riser Clamp Trap 3 In 11 1/2 In L
Supports and steadies 3-inch copper tube risers with a 300 lb maximum load
- Product typeDrain Components
- Supports copper tube risers up to 300 Lb load
- Copper-plated steel construction resists corrosion
- Fits 3-inch tube with 11 1/2 In length
- Meets A-A-1192A, WW-H-171-E, ANSI/MSS SP-69 and MSS SP-58 standards
- Secures with 3/8 In bolt for stable installation
3-Inch Copper-Plated Steel Riser Clamp
This Anvil riser clamp is designed for 3-inch copper tube risers in plumbing installations. It provides support and steadying for both insulated and non-insulated tubing. The clamp is manufactured from carbon steel with a copper-plated finish. It is not intended for use with hanger rods.
Sustained Load Capacity And Standards Compliance
The clamp carries a maximum load rating of 300 Lb for continuous vertical support. Construction follows A-A-1192A Type 8, WW-H-171-E Type 8, ANSI/MSS SP-69 and MSS SP-58 Type 8 standards. These specifications ensure the component maintains its rated capacity under constant pipe weight and thermal cycling.
Simple Bolt-Up Installation And Common Pitfalls
Installation uses the supplied 3/8-inch bolts to secure the two halves around the tube. The 11 1/2-inch overall length fits standard riser spacing without modification. A frequent error is attempting to suspend the clamp from hanger rods, which the design prohibits and which can lead to joint failure.
How it compares
Measured against everything we stock in Drain Stoppers, Strainers & Traps, at today’s prices. Recalculated every night.
- Price $14.99
- Cheaper than about 74% of the 4,240 comparable items (median $31.99).
Specifications
| Product | |
|---|---|
| Brand name | Anvil |
| Model name | 0500421086 |
| Product type | Drain Components |
Questions about this item
Does the Anvil 0500421086 riser clamp generate any noise, heat or draw power during continuous use?
No, the clamp is a passive copper-plated steel support with no moving parts, electrical connections or heat-generating components.
What pipe size must already be in place for the Anvil 0500421086 clamp to fit and function?
It is sized for 3-inch tube risers, either insulated or non-insulated, and uses a 3/8-inch bolt for securing.
Will the Anvil 0500421086 clamp work with older copper tube risers already installed in the system?
Yes, it supports and steadies existing copper tube risers up to a 300 lb maximum load and meets A-A-1192A, WW-H-171-E, ANSI/MSS SP-69 and MSS SP-58 Type 8 standards.
More in Drain Stoppers, Strainers & Traps
Similar items
Hommate Drain Cleaner Blue48-New-02 48 Sticks 4 Pack
- Drain Cleaner Blue4…
- Multi
Legris 3616 10 00 Push-Fit Union Fitting 10 mm Brass
- Drain Components
Banjo RB300-150 3 inch MNPT x 1-1/2 inch FNPT Reducing Bushing Schedule 80 trap
Nibco, Inc. 70735ALF-12 90° Hy-Set Elbow Trap 1/2 in
- Drain Components
- HAWA