We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

APC

APC AP8832 Metered PDU 100-120V 30A 24x5-20R 0U Vertical

SKU CH-B8NQ-F3R47 MPN AP8832

Metered vertical PDU delivers 100-120 V power through 24 NEMA 5-20R outlets with real-time load monitoring and a NEMA L5-30P input

  • Certified standardscUL Listed, FCC Part 15 Class A, ICES-003, PSE, UL 60950-1,
  • Supply voltage100 V, 120 V
  • Input line frequency50/60 Hz
  • Input current rating30A
  • Regulatory derated input current24A
  • Input connectionNEMA L5-30P
  • Active metering enables energy optimization and circuit protection
  • 24 NEMA 5-20R outlets deliver high-density power distribution
  • 0U vertical mounting saves rack space for IT equipment
  • NEMA L5-30P input supports 2.9 kW capacity with 9.8 ft cord
  • cUL and UL 60950-1 certifications ensure safety compliance

Metered 30A PDU for Rack Power Monitoring

The APC AP8832 is a metered power distribution unit built for 100V to 120V single-phase feeds at 30A. It supplies twenty-four NEMA 5-20R outlets from a single NEMA L5-30P input plug. Data centre managers use it to track real-time load and set alarm thresholds that warn before a circuit overloads.

Vertical 0U Mount with 10 ft Cord

The 0U vertical form factor installs alongside rack equipment without consuming horizontal rack units. A 9.8 ft input cord reaches floor-mounted or overhead power sources. Twenty-four front-facing 5-20R receptacles accept standard North American plugs and the unit carries cUL, UL 60950-1, FCC Class A, ICES-003 and PSE certifications.

Monitored Thermals and 2.9 kW Capacity

An integrated temperature and humidity sensor port lets environmental data feed into the same Web, SNMP or Telnet interface used for power metering. The PDU operates from -5 °C to 45 °C at up to 95 % relative humidity and 3000 m elevation. Overload protection is provided by ultra low-profile circuit breakers rated for the 24 A derated input.

How it compares

Measured against everything we stock in Rackmount PDUs, at today’s prices. Recalculated every night.

Price $660.99
Pricier than about 63% of the 643 comparable items (median $451.99).

New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.

Specifications

Product
Brand nameAPC
Model nameAP8832
Product typeMetered
Design styleVertical
Storage
Storage elevation0–15000 m
Power
Supply voltage100 V, 120 V
Input line frequency50/60 Hz
Input current rating30A
Regulatory derated input current24A
Input connectionNEMA L5-30P
Voltage output100 V, 120 V
Output outlets24 x NEMA 5-20R
Overload protectionYes
Size & build
Cord length10 ft (3.05 m)
Product dimensions70.5 in × 2.18 in × 1.72 in (H × W × D)
Product weight14.67 lb (6.65 kg)
Shipping weight10.43 kg
Package size2006 × 165 × 108 mm
Environment & compliance
Certified standardscUL Listed, FCC Part 15 Class A, ICES-003, PSE, UL 60950-1, UL Listed
RoHS complianceYes
Operating conditions-5–45 ºC
Operating humidity5–95%
Operating altitude0–3000 m
Storage temperature range-25–65 ºC
Storage relative humidity5–95%

Questions about this item

What does the NEMA L5-30P input cap at in practice?

The NEMA L5-30P input is rated for 30 A maximum, with a regulatory derated limit of 24 A continuous at 100–120 V, delivering up to 2.9 kW.

What mounting hardware does the 0U vertical design require?

The 0U vertical PDU mounts in the zero-U space of a standard rack using the included toolless mounting brackets; no extra rail kit is needed.

How is the unit configured after mounting, and what step is often missed?

Connect the 9.8 ft cord to the L5-30P source, then access the web, SNMP or Telnet interface to set alarm thresholds; users often skip the threshold setup and miss overload alerts.