APC AP8858 Metered PDU 20A 16A 208V 230V 18×C13 2×C19 0U
Metered 0U vertical rack PDU delivers 3.3 kW through eighteen C13 and two C19 outlets with 20 A input at 208 V or 16 A at 230 V
- Certified standardsCSA C22.2 No. 60950,IEC 60950,METI Denan,UL 60950-1,VDE
- Supply voltage200 V,208 V,230 V
- Input line frequency50/60 Hz
- Input current rating20A
- Regulatory derated input current16A
- Input connectionIEC-320 C20
- Metered input monitoring tracks 20A load in real time
- Eighteen C13 plus two C19 outlets support mixed server gear
- 0U vertical mounting preserves full rack height for equipment
- 8 ft input cord reaches distant PDU or UPS feeds
- Certified to UL 60950-1, CSA C22.2 No. 60950, IEC 60950, VDE and METI Denan
Metered 0U PDU for 20 A racks
This metered power distribution unit delivers 20 A at 208 V or 16 A at 230 V in a vertical 0U form factor. It is built for data-centre racks and server rooms that need real-time load visibility on each phase. The unit accepts a single IEC-320 C20 feed rated for 3.3 kW.
Eighteen C13 and two C19 outlets
The chassis provides eighteen IEC 320 C13 receptacles and two IEC 320 C19 receptacles for mixed-density deployments. Vertical mounting leaves horizontal rack space free for compute gear. Operating limits are -5 °C to 45 °C with 5 % to 95 % humidity.
Certifications and 9.8 ft input cord
Certifications include CSA C22.2 No. 60950, IEC 60950, METI Denan, UL 60950-1 and VDE with RoHS compliance. The 9.8 ft cord reaches floor or overhead power without extension leads. No software bundle is included; metering is read locally on the unit.
How it compares
Measured against everything we stock in Rackmount PDUs, at today’s prices. Recalculated every night.
- Price $547.99
- Pricier than about 56% of the 643 comparable items (median $451.99).
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Specifications
| Product | |
|---|---|
| Brand name | APC |
| Model name | AP8858 |
| Product type | Metered |
| Storage | |
| Storage elevation | 0–15000 m |
| Power | |
| Supply voltage | 200 V,208 V,230 V |
| Input line frequency | 50/60 Hz |
| Input current rating | 20A |
| Regulatory derated input current | 16A |
| Input connection | IEC-320 C20 |
| Voltage output | 100 V, 200 V, 208 V, 230 V |
| Output outlets | (18) IEC 320 C13 (2) IEC 320 C19 |
| Size & build | |
| Product dimensions | 35.5 in × 2.2 in × 1.72 in (H × W × D) |
| Product weight | 6.44 lb (2.92 kg) |
| Shipping weight | 4.99 kg |
| Package size | 1124 × 162 × 107 mm |
| Environment & compliance | |
| Certified standards | CSA C22.2 No. 60950,IEC 60950,METI Denan,UL 60950-1,VDE |
| RoHS compliance | Yes |
| Operating conditions | -5–45 ºC |
| Operating humidity | 5–95% |
| Operating altitude | 0–3000 m |
| Storage temperature range | -25–65 ºC |
| Storage relative humidity | 5–95% |
Questions about this item
What input connector does the AP8858 use and what current does it support?
The AP8858 uses an IEC-320 C20 inlet rated for a maximum input current of 20 A and a regulatory derated current of 16 A.
What are the dimensions of the AP8858 and what rack-mount style does it use?
The AP8858 measures 35.50" x 2.20" x 1.72" (H x W x D) and is designed for 0U vertical mounting.
How is the AP8858 installed and what step is often missed?
Mount the 0U PDU vertically in the rack using the supplied brackets, then secure the 9.8 ft input cord to the IEC-320 C20 inlet; the step often missed is locking the cord retention clip to prevent accidental disconnection.
More in Rackmount PDUs
Similar items
Tripp Lite PDUMH30NET Switched PDU 2.9 kW 120V 16 Outlets L5-30P 10ft 2U
- 2U
- 16 power availabili…
CyberPower CPS1215RM 120V 15A Basic PDU 10 Outlets 15ft NEMA 5-15P 1U
- 1U
- 1U
Tripp Lite PDUMV20 Metered PDU 20A 28 Outlets 120V 15ft 0U Vertical
- 0U
- 120 V
Schneider Electric AP7802B Metered PDU 2U 30A 120V 16x NEMA 5-20R
- 2U
- CSA , FCC Part 15 C…