We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

APC

APC AP8862 Metered PDU 20A 208V 3Ph 36x5-20R 0U

SKU CH-Z2M5-A2KB4 MPN AP8862

A 0U metered PDU distributing 208 V three-phase input to 36 NEMA 5-20R outlets at 120 V with 5.76 kVA capacity and local or remote load monitoring

  • Rack height0U
  • Certified standardscUL Listed, FCC Part 15 Class A, ICES-003, UL 60950-1, UL Li
  • RoHS complianceCompliant
  • Supply voltage208 V
  • Input line frequency50/60 Hz
  • Input current rating20A
  • Metered monitoring enables real-time power optimization
  • 36 NEMA 5-20R outlets support dense equipment deployments
  • 0U vertical form factor preserves valuable rack space
  • 76 kVA capacity handles high-density 3-phase loads
  • cUL and UL 60950-1 listed for verified safety compliance

Metered 3-Phase PDU for Data Centers

The APC AP8862 is a metered rack power distribution unit built for data-center racks that need active energy monitoring and circuit protection. It delivers 5.76 kVA at 208 V three-phase input and provides 120 V output through thirty-six NEMA 5-20R receptacles. Network interfaces including Web, SNMP and Telnet allow remote access and integration with APC centralized management platforms. A temperature and humidity sensor port adds environmental visibility.

Upgrade from Basic Unmetered Strip

This unit replaces a basic power strip that offers no real-time load data or alarm thresholds. The jump is worth it when operators must prevent overloads, balance phases across racks or report actual power consumption for capacity planning. Metered input with user-defined alerts enables proactive load management before a breaker trips. Locking receptacles and ultra-low-profile breakers add physical security and density that simple strips lack.

Check Rack Space and Input Wiring

Verify the rack can accommodate a 70.50-inch vertical or horizontal zero-U mount with toolless hardware. Confirm the facility provides a 208 V three-phase source with a NEMA L21-20P plug and that the 6-foot cord reaches the panel. Ensure the 16 A derated continuous rating matches the planned load and that local codes accept cUL, FCC Part 15 Class A and UL 60950-1 certifications.

How it compares

Measured against everything we stock in Rackmount PDUs, at today’s prices. Recalculated every night.

Price $705.99
Pricier than about 65% of the 643 comparable items (median $451.99).

New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.

Specifications

Product
Brand nameAPC
Model nameAP8862
Product typeMetered
Power
Supply voltage208 V
Input line frequency50/60 Hz
Input current rating20A
Regulatory derated input current16A
Input connectionNEMA L21-20P
Voltage output120 V
Output watts (va)5760 VA
Output outlets(36) NEMA 5-20R (Battery Backup)
Size & build
Rack height0U
Cord length6 ft (1.83 m)
Product dimensions70.5 in × 2.18 in × 1.72 in
Product weight13.29 lb (6.03 kg)
Shipping weight8.17 kg
Package size2006 × 165 × 108 mm
Environment & compliance
Certified standardscUL Listed, FCC Part 15 Class A, ICES-003, UL 60950-1, UL Listed
RoHS complianceCompliant

Questions about this item

What rack height and mounting style does the 70.50" long AP8862 require?

The unit is 70.50 inches long and supports both vertical 0U and horizontal rackmount orientations using toolless brackets.

How do you connect the 6 ft input cord to a three-phase source, and what step is often missed?

Plug the NEMA L21-20P connector into a compatible 208V 20A three-phase receptacle; the step often missed is confirming the branch circuit is derated to 16A per regulatory limits.

When should the ultra low-profile branch circuit breakers protecting the 36 NEMA 5-20R outlets be inspected or replaced?

Inspect the breakers after any overload trip or at least once per year; replace a breaker that no longer holds its 20A rating or shows physical damage.