We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

APC

APC AP8865 Metered 208V 30A Three-Phase PDU 44 Outlets 0U Vertical

SKU CH-RDND-9M5WZ MPN AP8865

Metered 208 V three-phase PDU delivers 44 locking outlets and real-time power monitoring in a 0U vertical form factor

  • Rack height0U
  • Certified standardsCSA C22.2 No. 60950,UL 60950-1
  • Supply voltage208 V 3PH
  • Input line frequency50/60 Hz
  • Regulatory derated input current24A
  • Input connectionNEMA L21-30P
  • Real-time metering enables load optimisation and circuit protection
  • 44 mixed outlets including 36 C13 6 C19 and 2 NEMA 5-20R
  • 0U vertical form factor preserves full rack height for equipment
  • 208 V three-phase 30 A input via NEMA L21-30P delivers 8.6 kW capacity
  • CSA and UL 60950-1 certified with RoHS compliance for regulated deployments

Three-Phase Metered PDU for High-Density Racks

The APC AP8865 is a 0U vertical power distribution unit built for three-phase 208V environments. It delivers 44 outlets — 36 IEC C13, six IEC C19, and two NEMA 5-20R — from a single NEMA L21-30P input rated at 8.6 kW. Data centre managers use it to monitor real-time power draw and balance loads across phases.

Tool-Less Vertical Mounting and Locking Outlets

The 0U form factor mounts in the zero-U space at the rear of a standard rack without consuming rack units. A 5.9 ft cord reaches side or top power feeds, while locking IEC receptacles prevent accidental disconnects during cable management. Installers must verify the facility provides a 30 A three-phase service with an L21-30P receptacle and 24 A derated capacity.

Continuous Monitoring Under Sustained Load

Metering circuitry reports per-phase current, voltage, and kilowatt-hours through Web, SNMP, and Telnet interfaces without interrupting output. User-defined alarm thresholds trigger local and remote alerts before the 24 A derated limit is reached. Operating range spans -5 °C to 45 °C and 5 % to 95 % humidity, so thermal drift does not degrade measurement accuracy during extended runs.

How it compares

Measured against everything we stock in Rackmount PDUs, at today’s prices. Recalculated every night.

Price $1,243.99
Pricier than about 82% of the 643 comparable items (median $451.99).

New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.

Specifications

Product
Brand nameAPC
Model nameAP8865
Product typeMetered
Storage
Storage elevation0–15000 m
Power
Supply voltage208 V 3PH
Input line frequency50/60 Hz
Regulatory derated input current24A
Input connectionNEMA L21-30P
Voltage output208 V
Output outlets36 x IEC 320 C13
(6) IEC 320 C19
(2) NEMA 5-20R
Overload protectionYes
Size & build
Rack height0U
Cord length6 ft (1.83 m)
Product dimensions70.51 in × 2.2 in × 1.81 in
Product weight16.67 lb (7.56 kg)
Shipping weight9.18 kg
Package size2000 × 162 × 107 mm
Environment & compliance
Certified standardsCSA C22.2 No. 60950,UL 60950-1
RoHS complianceYes
Operating conditions-5–45 ºC
Operating humidity5–95%
Operating altitude0–3000 m
Storage temperature range-25–65 ºC
Storage relative humidity5–95%

Questions about this item

How can I verify the AP8865 is metering correctly after installation?

Check the local display for real-time current readings per phase and confirm they match the expected load; then log into the Web, SNMP or Telnet interface to see the same values reported remotely.

What ships with the unit and which cords or sensors must be purchased separately?

The PDU includes the 5.9 ft NEMA L21-30P input cord and locking IEC C13/C19 receptacles; IEC C13/C19 power cords for servers and an optional temperature/humidity sensor are not included.

Which outlet mix should I choose for a rack with mostly C13 servers and a few high-power devices?

This model provides thirty-six C13 outlets for standard servers, six C19 outlets for higher-current equipment, and two NEMA 5-20R outlets for ancillary gear.

More in Rackmount PDUs

Similar items