APC AP8868 Metered PDU 10.0kW 208V 3PH 35A CS8365 (36) C13 (6) C19
A metered power distribution unit delivering 10.0 kW at 208 V three-phase with 36 C13 and 6 C19 outlets, 35 A input via CS8365 plug, and real-time load monitoring
- Rack height0U
- Certified standardscUL Listed,EN 55022 Class A,EN 55024,EN 61000-3-2,EN 61000-3
- Supply voltage208 V 3PH
- Input line frequency50/60 Hz
- Input current rating35A
- Input connectionCS8365
- Metered monitoring enables energy optimisation and circuit protection
- 0 kW output at 208 V three-phase powers dense rack loads
- 35 A maximum input current with CS8365 connector fits 35 A branch circuits
- 36 C13 plus 6 C19 outlets support mixed-density equipment
- ZeroU vertical form factor preserves horizontal rack space
10 kW 3-phase metered PDU
The APC AP8868 is a ZeroU metered rack power distribution unit rated for 10.0 kW at 208 V three-phase with a 35 A CS8365 input. It suits data-centre operators who need per-outlet energy visibility and overload alerts on high-density racks.
36 C13 and 6 C19 outlets
The unit provides thirty-six IEC 320 C13 and six IEC 320 C19 receptacles, allowing mixed server and networking gear to connect without adapter cables. Active metering with user-defined alarm thresholds delivers real-time local and remote warnings before a circuit approaches its 35 A limit.
208 V three-phase supply and 6 ft cord
Verify that the facility delivers 208 V three-phase power at 50 or 60 Hz and that the CS8365 plug matches the upstream receptacle. The 1.83 m cord length restricts placement to within that distance of the source, and the operating envelope is 0 to 55 °C at up to 95 % humidity.
How it compares
Measured against everything we stock in Rackmount PDUs, at today’s prices. Recalculated every night.
- Price $403.99
- Typical for this category: the median of 643 items is $451.99.
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Specifications
| Product | |
|---|---|
| Brand name | APC |
| Model name | AP8868 |
| Product type | Metered |
| Storage | |
| Storage elevation | 0–15000 m |
| Power | |
| Supply voltage | 208 V 3PH |
| Input line frequency | 50/60 Hz |
| Input current rating | 35A |
| Input connection | CS8365 |
| Voltage output | 208 V |
| Output watts (va) | 10.0 kW |
| Output outlets | (36) IEC 320 C13 (6) IEC 320 C19 |
| Overload protection | Yes |
| Size & build | |
| Rack height | 0U |
| Cord length | 6 ft (1.83 m) |
| Product dimensions | 72.01 in × 2.2 in × 2.01 in |
| Product weight | 18.78 lb (8.52 kg) |
| Environment & compliance | |
| Certified standards | cUL Listed,EN 55022 Class A,EN 55024,EN 61000-3-2,EN 61000-3-3,FCC Part 15 Class A,ICES-003,UL Listed,VCCI Class A |
| RoHS compliance | Yes |
| Operating conditions | 0–55 degree C |
| Operating humidity | 5–95% |
| Operating altitude | 0–3000 m |
| Storage temperature range | -25–65 ºC |
| Storage relative humidity | 5–95% |
Questions about this item
When will the IEC 320 C13 and C19 outlets need replacement under normal rack use?
The outlets are rated for the unit's 35 A maximum current draw and 10.0 kW capacity; replacement is only required if physical damage or overheating occurs during operation within the 0–55 °C range.
What is the first limit reached when running the PDU continuously at full 10.0 kW load?
The 35 A input current limit on the CS8365 connector is reached before any thermal or voltage threshold at 208 V three-phase.
How much heat does the AP8868 add to the rack when metering 10.0 kW all day?
As a passive distribution unit it adds negligible heat; the rack environment must simply stay within the 0–55 °C operating temperature and 5–95 % humidity limits.
More in Rackmount PDUs
Similar items
Tripp Lite PDU1230 PDU 30A 200/208/240V 16C13 4C19 L6-30P 15ft 1U
- 1U
- Tested to UL60950-1…
CyberPower CPS1215RM 120V 15A Basic PDU 10 Outlets 15ft NEMA 5-15P 1U
- 1U
- 1U
Tripp Lite PDUMH15NET2LX 1.4 kW Switched PDU 1U 8×5-15R 12.0 ft cord
- 1U
- Switched
Tripp Lite PDUMV20 Metered PDU 20A 28 Outlets 120V 15ft 0U Vertical
- 0U
- 120 V