APC AP8886 Metered PDU 0U 400V 32A 30×C13 12×C19
A 0U metered rack PDU delivering 230V from a 400V three-phase 32A feed, with 30 C13 and 12 C19 outlets and a local current display for overload prevention
- Rack height0U
- Certified standardsEN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC
- Supply voltage400 V 3PH
- Input line frequency50/60 Hz
- Input current rating32A
- Input connectionIEC 309 32A 3P+N+E
- Digital display shows real-time aggregate current draw to prevent overloads
- LED load indicator warns of overload and threshold breaches at a glance
- 30 IEC C13 and 12 IEC C19 outlets support dense 230 V equipment
- 0U vertical form factor fits 72 in rack height without consuming U-space
- 400 V three-phase 32 A input delivers up to 14.4 kW per branch whip
Metered 0U PDU for 400V three-phase racks
This metered power distribution unit mounts in a 0U form factor and accepts 400V three-phase input at up to 32A through an IEC 309 3P+N+E connector. It delivers 230V output to thirty C13 and twelve C19 locking receptacles. A local digital display shows aggregate current draw so installers can avoid overloads in high-density environments.
Interface limits of the IEC 309 32A input
The IEC 309 32A 3P+N+E plug restricts the unit to supplies that provide 400V three-phase power at 50 or 60 Hz with a matching socket. Maximum input current is capped at 32A, so total connected load must stay within that limit. Operating temperature range is 0 to 55 °C with humidity from 5 to 95 % non-condensing, and altitude up to 3000 m.
Forty-two locking outlets decide fit
The combination of thirty C13 and twelve C19 receptacles determines whether the PDU matches the cable ends on your servers and network gear. Both outlet types are IEC 320 locking style to prevent accidental disconnection. If your equipment uses different plug types or requires a different outlet count, this unit will not suit the rack.
How it compares
Measured against everything we stock in Rackmount PDUs, at today’s prices. Recalculated every night.
- Price $2,025.99
- Pricier than about 91% of the 643 comparable items (median $451.99).
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Specifications
| Product | |
|---|---|
| Brand name | APC |
| Model name | AP8886 |
| Product type | Metered |
| Storage | |
| Storage elevation | 0–15000 m |
| Power | |
| Supply voltage | 400 V 3PH |
| Input line frequency | 50/60 Hz |
| Input current rating | 32A |
| Input connection | IEC 309 32A 3P+N+E |
| Voltage output | 230 V |
| Output outlets | (30) IEC 320 C13 (12) IEC 320 C19 |
| Overload protection | Yes |
| Size & build | |
| Rack height | 0U |
| Product dimensions | 72 in × 2.2 in × 2 in (H × W × D) |
| Product weight | 19.18 lb (8.7 kg) |
| Shipping weight | 11.52 kg |
| Package size | 2050 × 170 × 112 mm |
| Environment & compliance | |
| Certified standards | EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC Part 15 Class A, ICES-003, VCCI Class A, VDE |
| RoHS compliance | Yes |
| Operating conditions | 0–55 °C |
| Operating humidity | 5–95% |
| Operating altitude | 0–3000 m |
| Storage temperature range | -25–65 ºC |
| Storage relative humidity | 5–95% |
Questions about this item
Should I choose a PDU with more C13 or more C19 outlets for my rack?
This unit provides 30 C13 outlets for standard server cords and 12 C19 outlets for high-power equipment, letting you match the mix to your devices.
What does the 32A rating mean for actual power delivery at 230V?
The 32A three-phase input at 400V supports up to 22kW total, with the metered display showing real-time aggregate current so you stay below the 32A limit per phase.
How does the IEC 309 32A 3P+N+E input connector limit installation options?
It requires a matching 32A three-phase supply with neutral and earth, common in European data centres, and fixes the maximum input current at 32A per phase.
More in Rackmount PDUs
Similar items
CyberPower CPS1215RM 120V 15A Basic PDU 10 Outlets 15ft NEMA 5-15P 1U
- 1U
- 1U
CyberPower PDU83108 3-Phase Switched PDU 60A 30 Outlets 200-240V
- Others
Tripp Lite PDU1230 PDU 30A 200/208/240V 16C13 4C19 L6-30P 15ft 1U
- 1U
- Tested to UL60950-1…