We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

APC

APC AP8965 Switched PDU 208V 30A 3PH 21 C13 3 C19 0U

SKU CH-ES87-0C5SN MPN AP8965

Switched three-phase PDU delivers 208 V power to twenty-one C13 and three C19 outlets with remote outlet control in a 0U vertical form factor

  • Rack height0U
  • Certified standardscUL Listed,FCC Part 15 Class A,ICES-003,UL Listed,VCCI Class
  • Supply voltage208 V 3PH
  • Input line frequency50/60 Hz
  • Input current rating30A
  • Regulatory derated input current24A
  • Switched outlet control enables remote power cycling per receptacle
  • Three-phase 208 V input delivers 8.6 kW capacity for dense loads
  • Twenty-one C13 and three C19 outlets support mixed equipment
  • 0U vertical mounting preserves rack space for servers
  • cUL and UL listed with FCC Part 15 Class A compliance

0U Vertical Switched PDU

The APC AP8965 is a zero-U vertical power distribution unit designed for high-density server racks. It accepts 208 V three-phase input through a NEMA L21-30P plug and provides twenty-one C13 and three C19 outlets. Network administrators can remotely power-cycle individual receptacles to recover unresponsive equipment without a site visit.

Sustained Load Behaviour

The unit carries a regulatory derated input current of 24 A against a 30 A maximum, delivering up to 8.6 kW across all phases. Overload protection trips when total draw exceeds the rated limit, preventing nuisance breaker trips during steady operation. It operates continuously from minus five to forty-five degrees Celsius at up to ninety-five percent relative humidity.

Installation Notes

Vertical 0U mounting uses the full rack height without consuming horizontal U-space, and the 5.9 ft input cord reaches nearby three-phase panels. The C13 and C19 outlets accept standard IEC 320 cables, but devices requiring other connector types will need adapters. Ensure the facility provides a compatible L21-30R receptacle and three-phase 208 V service before deployment.

How it compares

Measured against everything we stock in Rackmount PDUs, at today’s prices. Recalculated every night.

Price $1,415.99
Pricier than about 87% of the 643 comparable items (median $451.99).

New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.

Specifications

Product
Brand nameAPC
Model nameAP8965
Product typeSwitched
Storage
Storage elevation0–15000 m
Power
Supply voltage208 V 3PH
Input line frequency50/60 Hz
Input current rating30A
Regulatory derated input current24A
Input connectionNEMA L21-30P
Voltage output208 V
Output outlets(21) IEC 320 C13
(3) IEC 320 C19
Overload protectionYes
Size & build
Rack height0U
Cord length6 ft (1.83 m)
Product dimensions72.01 × 2.2 × 2.01 in
Product weight18.03 lb (8.18 kg)
Shipping weight10.89 kg
Package size211 × 165 × 124 mm
Environment & compliance
Certified standardscUL Listed,FCC Part 15 Class A,ICES-003,UL Listed,VCCI Class A
RoHS complianceYes
Operating conditions-5–45 ºC
Operating humidity5–95%
Operating altitude0–3000 m
Storage temperature range-25–65 ºC
Storage relative humidity5–95%

Questions about this item

Does the 30 A three-phase input or the 24 A derated limit generate noticeable heat when the unit runs continuously?

The PDU operates between –5 °C and 45 °C with no active cooling mentioned, so heat output stays within that range under the 24 A derated load.

My rack only has C13 and C19 cords — will the 21 C13 and 3 C19 outlets accept them directly?

Yes, the 21 IEC 320 C13 and 3 IEC 320 C19 receptacles match standard C13 and C19 plugs without adapters.

Can I keep my older single-phase 208 V gear on the same three-phase NEMA L21-30P feed?

The unit delivers 208 V from a three-phase 30 A source; single-phase 208 V devices can connect to the C13 or C19 outlets as long as total draw stays within the 24 A derated limit.