APC Metered Rack PDU Zero U 30A 120V (24)5-20 AP7832
Zero U metered PDU distributes 120 V power through twenty-four NEMA 5-20R outlets with a NEMA L5-30P input and 10-foot cord
- Product typeBasic
- Metered monitoring tracks real-time load on 24 outlets
- Zero-U vertical design fits 63.75-inch rack height without using U-space
- 30 A input capacity delivers 2880 VA at 120 V
- 10-foot cord with NEMA L5-30P plug reaches distant power sources
- Built-in overload protection safeguards connected equipment
Metered Rack PDU 30A 120V
The APC AP7832 is a Zero U metered power distribution unit that delivers 120V output from a NEMA L5-30P input. It provides 24 NEMA 5-20R outlets and a 10-foot cord for rack mounting in server rooms and network closets. Local metering displays the aggregate load so operators can monitor power consumption at a glance.
Suits 120V racks needing outlet density.
This unit fits environments that run 100V or 120V single-phase service and require 24 outlets in a compact vertical form factor. It is not suitable for sites that need per-outlet switching, remote reboot capability, or input voltages other than 100V and 120V.
24 NEMA 5-20R outlets at 2880 VA
The single specification that determines fit is the 24 NEMA 5-20R outlets fed by a 30A 120V input with a 2880 VA load capacity. If the equipment requires a different receptacle type, a higher voltage, or switched outlet management, this PDU will not meet the requirement.
How it compares
Measured against everything we stock in Rackmount PDUs, at today’s prices. Recalculated every night.
- Price $159.99
- Cheaper than about 77% of the 643 comparable items (median $451.99).
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Specifications
| Product | |
|---|---|
| Product type | Basic |
Questions about this item
What rack height and mounting orientation does the 63.75-inch Zero U PDU require?
The unit mounts vertically in a standard 19-inch rack using its full 63.75-inch length; Zero U design means it occupies no horizontal rack units.
How do I connect the 10-foot input cord to a 30 A 120 V source, and what common wiring mistake should I avoid?
Plug the NEMA L5-30P connector into a matching 30 A receptacle; do not use an adapter that defeats the locking feature or exceed the 24 A per-phase limit.
When should I plan to replace the internal surge-protection components in this metered PDU?
APC recommends replacing the surge module after a major over-voltage event or when the front-panel indicator shows end-of-life, typically every three to five years under normal loads.
More in Rackmount PDUs
Similar items
Tripp Lite PDUMV15 Metered PDU 15A 16 Outlets 5-15R 120V 5-15P 15ft Cord 0U Vertical
- 0U
- Tested to UL60950-1…
CyberPower CPS1215RM 120V 15A Basic PDU 10 Outlets 15ft NEMA 5-15P 1U
- 1U
- 1U
Tripp Lite PDUMV20-24 20A Metered Vertical PDU 0U 24in 6x5-15/20R L5-20P 15ft
- 0U
- Digital ammeter dis…
Tripp Lite PDUMV20 Metered PDU 20A 28 Outlets 120V 15ft 0U Vertical
- 0U
- 120 V
Tripp Lite PDUMH20 1.92kW 120V 12x 5-15/20R L5-20P/5-20P 1U PDU
- 1U
- 1U