We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
A 2-inch hazardous-location conduit union connects rigid conduit to a box with chromate-coated iron construction
This Appleton Century Crofts UNY200NR connects 2-inch rigid conduit to a box using a straight male-to-female union. The malleable iron body carries a chromate, powder and electroplated finish. It is rated for Class I Division 1 and 2 Groups A through D, Class II Division 1 and 2 Groups E, F, G and Class III hazardous locations.
Standard conduit unions lack the hazardous-location ratings required where flammable gases, vapours, dusts or fibres are present. The jump is worth it when the installation must meet Class I, Class II or Class III Division requirements and the conduit run uses 2-inch rigid metal conduit in vertical or horizontal orientation.
Confirm the existing conduit is 2-inch trade size rigid metal type before ordering. The fitting provides 2-inch FNPT by 2-inch MNPT ends, so both the box entry and the conduit coupling must match these thread specifications. Overall length is 3 5/8 inches; ensure adequate space within the enclosure.
Measured against everything we stock in Electrical Conduit & Fittings, at today’s prices. Recalculated every night.
| Product | |
|---|---|
| Brand name | APPLETON ELECTRIC |
| Product type | Conduit Fittings |
| Color and finish | Silver |
| Size & build | |
| Size (in.) | 2 in (5.08 cm) |
The union measures 3 5/8 in long, so allow at least that much straight space between the rigid conduit end and the box entry for the fitting to sit flush without binding.
Thread the male NPT end into the box or female hub first, then spin the female NPT end onto the rigid conduit; reversing the order often cross-threads the male fitting.
Inspect the coating at each scheduled conduit-system audit — typically annually — and replace the union if any bare iron or flaking is visible, because the hazardous-location rating depends on intact corrosion protection.
More in Electrical Conduit & Fittings
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?