Ashcroft CX8MB242P5IW Pressure Transducer 0.5 in WC
Measures differential pressure from 0 to .5 in WC with a 4 to 20mA output and .80% accuracy
- Product typeElectronic
- Accurate low-pressure monitoring with ±0.80 % full-scale precision
- Reliable 4–20 mA loop output over two wires
- Wide 12–36 V DC supply range simplifies integration
- Safe plastic housing rated NEMA 1 and UL94-5VA
- Durable brass hose-barb fitting withstands 15 psid overpressure
Product identity
The Ashcroft CX8MB242P5IW is a differential pressure transducer calibrated for a 0 to 0.5 in WC range. It delivers a 4 to 20 mA DC output signal powered by a 12 to 36V DC supply. The unit uses a two-wire loop configuration with screw-terminal connections and a 1/4 in male hose barb process fitting.
Suitable applications
This transmitter suits HVAC and building-automation tasks that require low-pressure differential monitoring with NEMA 1 enclosure protection. The +/-0.80 percent full-scale accuracy and plastic housing limit its use in high-vibration, wash-down or hazardous-area installations where a higher IP rating or ruggedised metal housing is required.
Sustained-load behaviour
The brass fitting and plastic housing withstand a 15 psid overpressure limit and a 25 psid burst rating during continuous operation. The UL94-5VA rated housing material maintains its flammability classification under prolonged thermal stress. The two-wire 4 to 20 mA loop maintains signal integrity over long cable runs without voltage-drop errors that affect voltage-output devices.
How it compares
Measured against everything we stock in Meters, Testers & Measuring Tools, at today’s prices. Recalculated every night.
- Price $128.99
- Pricier than about 69% of the 3,030 comparable items (median $54.99).
Specifications
| Product | |
|---|---|
| Brand name | ASHCROFT |
| Product type | Electronic |
Questions about this item
What power supply do I need to run the CX8MB242P5IW transducer?
Provide 12 to 36V DC to the two-wire screw terminals; the loop draws 4 to 20mA DC.
Can I connect the 1/4 in hose-barb fitting to my existing brass manifold?
Yes, the male 1/4 in hose barb is brass and threads into standard 1/4 in NPT female ports.
How do I verify the transducer is calibrated correctly after wiring?
Apply 0 in wc and confirm 4 mA output, then apply .5 in wc and confirm 20 mA output within .80 percent full-scale accuracy.
More in Meters, Testers & Measuring Tools
Similar items
WUQ MH13 250V-2500V Insulation Resistance Tester 1M-200G 2000 Counts LCD 100 Data Storage
- Test Instrument & G…
WUQ Bilateral Laser Distance Meter DM-262 80m measurement tool
- Test Instrument & G…
Ashcroft 451379 Process Pressure Gauge 0-400 psi 4 1/2 in Dial
- Black
- Electronic