APC APCRBC158 UPS Replacement Battery for BX1000M
- Battery
- APCRBC158, APC
We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
12V 2.3Ah sealed lead-acid battery with F1 terminal fits AP-1229 UPS, uses AGM technology for maintenance-free, leak-proof operation with 90% gas recombination and 100% OEM compatibility
The BatteryJack inc. 12V 2.3Ah sealed lead-acid battery serves as a direct replacement for AP-1229 UPS units. It uses advanced AGM technology to deliver maintenance-free backup power for servers and network equipment. The F1 terminal design ensures a secure connection without soldering. Buyers needing higher capacity or different terminal types should select another model.
The absorptive glass mat system absorbs electrolyte to prevent leakage and supports safe operation in any orientation. Gas recombination technology recombines over 90 percent of generated gas during normal use, keeping internal pressure stable. Sealed construction eliminates the need for water top-ups or specific gravity checks. The battery produces no audible noise and draws no power while on standby.
The F1 terminal matches the original AP-1229 connector for tool-free installation inside compatible UPS housings. Non-spillable classification meets international air transport requirements for safe shipping and handling. Position-free design allows horizontal or vertical mounting without leakage risk. Expected service life spans four to seven years under typical floating charge conditions.
Measured against everything we stock in UPS Replacement Batteries, at today’s prices. Recalculated every night.
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
No published specifications for this item yet.
Insert the battery with the F1 terminals facing the correct polarity, then firmly press each quick-disconnect connector onto its terminal until it clicks; the step often missed is verifying both connectors are fully seated before closing the UPS cover.
The battery is maintenance-free with no watering or specific-gravity checks required; plan to replace the unit once runtime drops below acceptable levels, typically after 4-7 years of float service.
The 2.3 Ah capacity sets the runtime ceiling; under continuous discharge the voltage will fall to the UPS cut-off threshold, ending usable output before thermal limits are reached.
More in UPS Replacement Batteries
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?