Burndy Two Conductor Lugs 6AWG 4.5In
Dual-conductor aluminum lug accepts 6 AWG to 350 kcmil copper, 600 V rated with 1/2 in stud holes on 1.75 in centres
- Product typeCommercial
- Dual-conductor design simplifies parallel runs
- Rated 600 V for standard service panels
- 194 °F max temperature handles heavy loads
- Slotted head speeds up field installation
- 75 in hole spacing fits common bus bars
Two-Conductor Lug for 6 AWG Copper
This Burndy mechanical connector accepts stranded copper wire from 6 AWG up to 350 kcmil and provides two termination points in a single aluminium body. It is designed for commercial electrical installations that require a reliable lug connection on a 1/2 inch stud.
Dual-Hole Pattern with 1.75 Inch Spacing
The lug features two mounting holes of 0.56 inch diameter spaced 1.75 inches apart, fixing the tongue orientation and preventing rotation under vibration. This hole pattern is the critical dimension that determines whether the lug fits the existing busbar or equipment pad.
Rated for 600 Volts at 194 Degrees F
Aluminium construction and a slotted head style allow the connector to operate continuously at up to 194 degrees Fahrenheit while carrying rated current at 600 volts. The 0.31 inch tongue thickness and 2.31 inch width distribute clamping force evenly across both conductors during sustained thermal cycling.
How it compares
Measured against everything we stock in Wire, Cable & Wiring Supplies, at today’s prices. Recalculated every night.
- Price $23.99
- Typical for this category: the median of 1,610 items is $25.99.
Specifications
| Product | |
|---|---|
| Brand name | Burndy |
| Product type | Commercial |
Questions about this item
What does the 350 kcmil maximum copper size mean when I install these lugs?
It sets the upper limit for stranded copper conductors; any wire larger than 350 kcmil will not fit the connector barrel.
How does the 600 V rating limit the circuits I can use these on?
The lugs are rated for a maximum of 600 V, so they are suitable for low-voltage and 600 V class power circuits but not for higher-voltage systems.
What stud size and hole spacing do I need to match for the two-hole mounting?
The lugs require a 1/2 in stud and have two holes spaced 1.75 in apart with a 0.56 in diameter.
More in Wire, Cable & Wiring Supplies
Similar items
3M M6-38RX Ring Terminal 3/8 in Stud 6 AWG 1000 V Bare
- Electrical Connecto…
PREMIERE RACEWAY PRODUCTS Wire Hider FRA-33414 1-1/2" White Right Angle Self Adhesive
Burndy YAD31M10E38 One-Hole Compression Lug 300 kcmil 3/8 in Stud Long
- Electrical Connecto…
PREMIERE RACEWAY PRODUCTS 53414 1-1/2" Outside Corner White Self Adhesive
Hubbell Incorporated GFRTW20I GFCI Receptacle 20A 125VAC 5-20R
- Wiring Devices