Bussmann 16325-2 Power Distribution Block 2 Pole 350 A 600 V
Two-pole open distribution block rated 350 A at 600 V, accepting 14 AWG to 2/0 AWG line and 14 AWG to 4 AWG load copper conductors
- Brand nameEATON BUSSMANN
- Two-pole block distributes up to 350 A at 600 V
- Accepts line conductors from 14 AWG to 2/0 AWG copper
- Six load terminals per pole handle 14 AWG to 4 AWG copper
- Compact footprint measures 6.5 in long by 3.75 in deep
- Open design suits industrial panels and generator hook-ups
Two-Pole Power Distribution Block
The Bussmann 16325-2 is a two-pole power distribution block rated for 350 A and 600 V AC/DC. It accepts copper or aluminum conductors and is designed for industrial power supply applications requiring a compact, open-style block.
Conductor Range and Voltage Limits
Each pole provides two line connections for copper wire from 14 AWG up to 2/0 AWG and six load connections for copper wire from 14 AWG up to 4 AWG. The block is rated for a maximum of 600 V AC/DC and 350 A with copper conductors, defining the practical limits for safe operation.
Open-Style Mounting and Wiring Access
The open design measures 6.5 in overall length and 3.75 in overall depth, giving clear access to all termination points for straightforward installation. Installers must verify conductor sizes stay within the stated AWG ranges and ensure proper torque on each connection to avoid overheating.
How it compares
Measured against everything we stock in Bench & DC Power Supplies, at today’s prices. Recalculated every night.
- Price $112.99
- Pricier than about 77% of the 677 comparable items (median $33.99).
Specifications
| Product | |
|---|---|
| Brand name | EATON BUSSMANN |
Questions about this item
How do I choose between the 2-pole 350 A version and other capacities?
This model is a single 2-pole block rated for 350 A with copper conductors at 600 V AC/DC; other pole counts or ampacities would be different part numbers.
What does the 350 A rating mean once the block is installed in a panel?
It indicates the maximum continuous current each pole can carry using copper wire up to 2/0 AWG on the line side and 4 AWG on the load side without exceeding temperature limits.
How does the 600 V AC/DC rating cap what I can connect?
The 600 V rating limits the block to circuits where the nominal voltage does not exceed 600 V AC or DC, regardless of the 350 A current capacity.
More in Bench & DC Power Supplies
Similar items
Eaton 10250T122-53 Mushroom Head Push Button 30 mm Red 1NO
- EATON
- 30 mm
Samlex America Evolution F Series 1200W 120V Pure Sine Wave Inverter Charger 24V 40A
- Samlex America
Schneider Electric XB4BS9442 22 mm 1NC Emergency Stop Push Button Red
- SCHNEIDER ELECTRIC
- 22 mm
Schneider Electric 9001KY2 30 mm 2-Hole Aluminum Enclosure
- SCHNEIDER ELECTRIC
Samlex America Programmable Remote Control EVO-RC-PLUS for Evolution F Series Inverter/Charger
- Samlex America