Bussmann 16500-1 Power Distribution Block 1 Pole 620 A Copper
Single-pole copper power distribution block rated 620 A at 600 V with two line and two load connections for 6 AWG to 350 kcmil conductors
- Brand nameEATON BUSSMANN
- Handles high loads with 620 A copper rating
- Connects large cables up to 350 kcmil
- Works at 600 V for industrial power
- Single-pole open block simplifies wiring layout
- Compact 2.89 in depth fits tight panels
Power Distribution Block 620 A Copper
The Bussmann 16500-1 is a single-pole power distribution block rated for 620 A with copper conductors. It accepts copper or aluminium wire from 6 AWG up to 350 kcmil on both line and load sides, providing two connections per pole. The open-design unit mounts on a surface and operates at up to 600 V with an overall depth of 2.89 in.
Suits single-pole high-current distribution
This block suits panels that need to split or join heavy copper feeds in a single-pole arrangement. It is not for installers who require multiple poles in one housing, or for systems that demand a higher voltage rating than 600 V. Buyers needing integral stud terminations or a different mounting style should look at other configurations.
620 A copper rating decides fit
The 620 A maximum current with copper conductor is the figure that determines whether this block matches the load. If the circuit calls for a higher ampacity or a lower maximum wire size, another block must be chosen.
How it compares
Measured against everything we stock in Bench & DC Power Supplies, at today’s prices. Recalculated every night.
- Price $125.99
- Pricier than about 80% of the 677 comparable items (median $33.99).
Specifications
| Product | |
|---|---|
| Brand name | EATON BUSSMANN |
Questions about this item
How do I install the 16500-1 block and which step is commonly missed?
Surface-mount the single-pole block, then terminate up to two line and two load conductors per pole in the 6 AWG to 350 kcmil range, torquing each set-screw to the manufacturer's specified value — the step often skipped is verifying torque on every connection.
What maintenance or replacement will the 16500-1 block need over time?
Periodically inspect all set-screw terminals for discoloration or looseness and re-torque to spec; replace the block if any connector shows heat damage, cracking, or can no longer hold 6 AWG to 350 kcmil conductors securely.
At sustained loads, what limit of the 16500-1 block is reached first?
The 620 A copper-conductor rating is the first hard limit; continuous operation above that current will overheat the terminals before the 600 V insulation rating becomes a factor.
More in Bench & DC Power Supplies
Similar items
Analog Technologies, Inc. AHV12V500V10MAW 12V 500V 10mA industrial power supply
- 500 V
- 10 mA
Samlex America Evolution F Series 1200W 120V Pure Sine Wave Inverter Charger 24V 40A
- Samlex America
Schneider Electric 9001KY2 30 mm 2-Hole Aluminum Enclosure
- SCHNEIDER ELECTRIC
Tycon Systems TP-VRHP-2456 DC Voltage Converter 18-36V 56V 1.25A 70W
- Tycon Systems