Bussmann PDBFS330 Power Distribution Block 380A 1P 6P Secondary 600V
Single-pole power distribution block rated 380 A at 600 V AC/DC with one primary input for 6 AWG to 500 MCM and six finger-safe secondary outputs for 14 to 2 AWG
- Brand nameBUSSMANN
- Handles heavy loads with 380 A rating
- Finger-safe design prevents accidental contact
- One primary input accepts 6 AWG to 500 MCM
- Six secondary outputs take 14 to 2 AWG
- UL 1953 and CSA 6228-01 listed for compliance
380 A single-pole distribution block
The Bussmann PDBFS330 is a finger-safe power distribution block rated for 380 A at 600 V AC/DC. It provides one primary connection accepting 6 AWG to 500 MCM conductors and six secondary connections for 14 AWG to 2 AWG wires. The unit suits industrial panels that need to split a single high-current feed into multiple branch circuits.
Finger-safe housing and 600 V rating
The block carries UL 1953 listing, CSA Class 6228-01 certification and CE Component IEC marking. Its enclosed design shields live parts during routine maintenance, reducing accidental contact risk. The 600 V rating supports standard North American control-voltage and three-phase distribution voltages without additional insulation barriers.
Replaces open terminal strips and multi-block arrays
Installers upgrading from bare bus bars or ganged terminal strips gain consolidated wiring and touch-safe clearance in a 4.67 in by 2.95 in by 1.55 in footprint. The jump is worth it when a single 380 A feed must serve six branch circuits and code requires finger-safe protection. Panels needing more than one pole or higher pole-count distribution will require additional blocks.
How it compares
Measured against everything we stock in Bench & DC Power Supplies, at today’s prices. Recalculated every night.
- Price $142.99
- Pricier than about 82% of the 677 comparable items (median $33.99).
Specifications
| Product | |
|---|---|
| Brand name | BUSSMANN |
Questions about this item
How do I mount the PDBFS330 and torque the primary lug for 500 MCM wire?
Secure the block using its 4.67 in length and 1.55 in width mounting points; torque the single primary lug per pole to the manufacturer value for 6 AWG to 500 MCM conductors.
Which parts of the PDBFS330 need periodic inspection or replacement?
Check the six secondary terminals per pole for 14 to 2 AWG wire security and the finger-safe covers for cracks; replace the block if any contact shows overheating or damage.
At what current does the PDBFS330 reach its thermal limit during continuous operation?
The block is rated 380 A at 600 V AC/DC; sustained loads above this value will hit the thermal limit first.
More in Bench & DC Power Supplies
Similar items
Mersen MPDB69093 Power Distribution Block 3 Pole 760 A 1000 V
- MERSEN
Samlex America Evolution F Series 1200W 120V Pure Sine Wave Inverter Charger 24V 40A
- Samlex America
Schneider Electric 9001K1L1G Illuminated Push Button 30 mm Green
- SCHNEIDER ELECTRIC
- 30 mm
Schneider Electric 9001KY2 30 mm 2-Hole Aluminum Enclosure
- SCHNEIDER ELECTRIC