Carol E3514S.41.03 industrial wire 16/4 1000 ft
Four-conductor solid 16 AWG plenum-rated fire alarm cable on a 1,000 ft reel in a box
- Product typeWire & Cable
- Plenum-rated fire-alarm cable meets NEC 725 CL3P, 760 FPLP, 800 CMP
- 16 AWG solid conductors handle 300 V for reliable signal transmission
- Four unshielded conductors simplify termination in alarm and audio systems
- Red PVC jacket resists flame spread and identifies circuits at a glance
- 1000 ft reel-in-a-box supplies long pulls with .2 in outside diameter
Carol E3514S.41.03 fire alarm cable
This Carol E3514S.41.03 cable is a plenum-rated fire alarm wire supplied on a 1000 ft reel in a box. It uses four solid 16 AWG conductors with PVC insulation and a red PVC jacket. The unshielded design meets NEC articles 725 CL3P, 760 FPLP and 800 CMP for power-limited circuits. Installers use it for alarm systems and audio systems in commercial buildings.
Replaces non-plenum cable in air-handling spaces
This cable upgrades installations that previously used non-plenum wire in ducts or return-air plenums. The jump is worth it when local code requires a CMP or FPLP rating to limit flame spread and smoke. The 300 V rating suits typical power-limited signalling circuits. It is not for applications that demand shielded pairs or stranded conductors for frequent flexing.
Solid conductors hold shape in long pulls
Under sustained installation tension the solid 16 AWG conductors resist stretching and hold their geometry through conduit bends. The 0.2 in outside diameter keeps fill ratios low in crowded raceways. The PVC jacket withstands the heat of plenum environments without degrading during the service life of the alarm system.
How it compares
Measured against everything we stock in Wire, Cable & Wiring Supplies, at today’s prices. Recalculated every night.
- Price $476.99
- Pricier than about 91% of the 1,610 comparable items (median $25.99).
Specifications
| Product | |
|---|---|
| Brand name | CAROL |
| Product type | Wire & Cable |
Questions about this item
What conduit size accommodates the 0.2 in outside diameter?
Choose conduit sized for a 0.2 in cable diameter to stay within fill limits; consult local code for exact trade size.
How is the solid 16 AWG conductor terminated, and what mistake should be avoided?
Strip each solid conductor cleanly, seat fully in the terminal, and do not over-tighten screws which can nick the 16 AWG wire.
When should the PVC jacket be inspected for replacement?
Inspect the red PVC jacket after any exposure to heat, chemicals, or physical damage; replace the cable if the jacket shows cracking or discoloration.
More in Wire, Cable & Wiring Supplies
Similar items
Zoro Select 3001829 Bronze Screen 60 in W 50 ft L 0.011 in Wire Dia
- Wire Fabric
PREMIERE RACEWAY PRODUCTS Wire Hider FRA-33414 1-1/2" White Right Angle Self Adhesive
Allen-Bradley 1756-OB16E ControlLogix 16 Point D/O Module
- Power Supply Cord
PREMIERE RACEWAY PRODUCTS 53414 1-1/2" Outside Corner White Self Adhesive
Tyrap TY29M Industrial Wire Cable Tie 30.3 in 120 lb
- Cable Management &…