CyberPower PDU33108 PDU 3-Phase 200-240V 50A 42 Outlets 10ft Hubbell CS8365C 0U LCD
Three-phase monitored PDU distributes 200–240 V at 35 A derated load through 36 C13 and 6 C19 outlets on a 10 ft cord with Hubbell CS8365C plug
- 3-phase power distributes load across 200-240V supply
- 42 outlets (36 C13 + 6 C19) support dense rack deployments
- Monitored PDU sends email, SMS and SNMP trap alerts
- 50A input derated to 35A for continuous safe operation
- Vertical 0U form factor with LCD saves rack space
Three-Phase Monitored PDU
The CyberPower PDU33108 is a three-phase monitored power distribution unit that operates at 200V-240V with a 50A input derated to 35A. It mounts vertically in a 0U rack footprint and provides 42 outlets in total. A 10ft cord terminates in a Hubbell CS8365C plug and an integrated LCD display shows local metering data.
High-density racks needing remote alerts
This unit suits data-centre racks that require outlet-level monitoring with email, SMS text and SNMP trap notifications. The mix of 36 IEC-320 C13 and 6 IEC-320 C19 outlets supports dense server and network gear deployments. Facilities limited to single-phase supply or lower amperage service should look at alternative power distribution units.
42-outlet count with C13/C19 mix
The single specification that decides fit is the outlet configuration of 36 C13 and 6 C19 receptacles delivering 42 connections from one vertical chassis. Match this count and connector mix to your equipment cable inventory before purchase. The 35A derated capacity and three-phase 200V-240V input must also align with your facility power.
How it compares
Measured against everything we stock in Rackmount PDUs, at today’s prices. Recalculated every night.
- Price $1,219.99
- Pricier than about 82% of the 643 comparable items (median $451.99).
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Specifications
| Size & build | |
|---|---|
| Shipping weight | 11.79 kg |
| Package size | 2007 × 210 × 152 mm |
Questions about this item
Are the IEC-320 C13 and C19 outlets user-replaceable if one fails?
The 36 C13 and 6 C19 outlets are fixed on the vertical chassis; failed outlets require whole-unit service rather than individual replacement.
At what sustained load does the 35 A derating become the limiting factor?
Continuous draw above 35 A on the 3-phase input triggers the derated limit before the 50 A plug rating is reached.
How much heat does the unit add to a rack when fully loaded all day?
The monitored PDU itself draws only a few watts for its LCD and network card, so nearly all heat comes from the connected equipment, not the distribution unit.
More in Rackmount PDUs
Similar items
APC AP7731 Switched Rackmount PDU 30A NEMA L6-30P 8ft
- FCC Part 15 Class A…
- Switched
CyberPower CPS1215RM 120V 15A Basic PDU 10 Outlets 15ft NEMA 5-15P 1U
- 1U
- 1U
CyberPower PDU81102 30A Switched Metered-by-Outlet PDU 24 Outlets 10ft NEMA L5-30P Vertical 0U LCD
- Consumer Electronics
Tripp Lite PDUMV20 Metered PDU 20A 28 Outlets 120V 15ft 0U Vertical
- 0U
- 120 V
Eaton EMI200-10 Metered PDU 5.76 kVA 34 Outlet 120/230V L14-30P
- 120 V AC, 230 V AC
- 120 V AC, 230 V AC