CyberPower PDU44006 Switched ATS PDU 1U 10 Outlets 2x L6-20P 8x C13 2x C19
Switched ATS PDU with dual L6-20P inputs and ten outlets — eight C13 and two C19 — for 200-240 V rack power redundancy
- Connection optionsEthernet (RJ45) Serial (RJ45)
- Rack height1U
- Remote management protocolIPv4, TCP/IP, UDP, SNMPv1, HTTP, NTP, DNS, Telnet, DHCP, SMT
- Front panel ledsSource Status Source Selected Output Normal/Warning/Critical
- Certified standardsEnvironmental RoHS Compliant Safety UL62368 FCC Class A cTUV
- Supply voltage240 – 200 VAC
- Switched ATS provides automatic failover between two 200–240 VAC sources
- 1U rackmount form factor fits standard cabinets with 10 ft input cords
- 10 locking outlets (8 C13, 2 C19) support diverse server and network gear
- Remote management via Ethernet and serial using IPv4, IPv6, SNMPv3, SSH, TLS and more
- Front-panel LEDs show source status, selected source, output state and network link health
Switched ATS PDU 1U
The CyberPower PDU44006 is a switched automatic-transfer-switch power distribution unit that fits a single rack unit. It delivers ten outlets — eight IEC-320 C13 and two IEC-320 C19 — from dual NEMA L6-20P inputs. Network and serial ports give administrators remote control over every outlet and power source.
Upgrade from basic PDU
A basic PDU only distributes power; this unit adds automatic source switching and per-outlet switching over IP. The jump is worth it when you need redundant 200-240 VAC feeds and the ability to reboot individual devices without visiting the rack.
Sustained-load behaviour
The regulatory derated input current is 16 A continuous across the 200-240 VAC range. Front-panel LEDs show source status, selected source, output state and normal/warning/critical thresholds in real time. Operating temperature spans 0-45 °C with humidity up to 95 % non-condensing.
How it compares
Measured against everything we stock in Rackmount PDUs, at today’s prices. Recalculated every night.
- Price $977.99
- Pricier than about 75% of the 643 comparable items (median $451.99).
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Specifications
| Product | |
|---|---|
| Brand name | CyberPower |
| Product line | Switched ATS PDU Series |
| Model name | PDU44006 |
| Part number | PDU44006 |
| Product type | Switched |
| Design style | Rackmount |
| Storage | |
| Storage elevation | 0 – 49213 ft (0 – 14999 m) |
| Display | |
| Front panel leds | Source Status Source Selected Output Normal/Warning/Critical Status Tx/Rx LINK Outlets |
| Connectivity | |
| Connection options | Ethernet (RJ45) Serial (RJ45) |
| Power | |
| Supply voltage | 240 – 200 VAC |
| Input line frequency | 50 Hz – 60 Hz |
| Input current rating | 20A |
| Regulatory derated input current | 16 A |
| Input connection | 2 x NEMA L6-20P |
| Voltage output | 240 – 200 VAC |
| Output outlets | 8 – IEC-320 C13 2 – IEC-320 C19 |
| Size & build | |
| Rack height | 1U |
| Cord length | 10 ft (3.0 m) |
| Product dimensions | 17.05 × 1.75 × 8.45 (in) |
| Product weight | 8.3 (lb) |
| Shipping weight | 6.58 kg |
| Package size | 550 × 398 × 124 mm |
| Environment & compliance | |
| Certified standards | Environmental RoHS Compliant Safety UL62368 FCC Class A cTUVus |
| RoHS compliance | Yes |
| Operating conditions | 32 – 113 °F (0 – 45 °C) |
| Operating humidity | 0 – 95 % (non-condensing) |
| Operating altitude | 0 – 13123 ft (0 – 4000 m) |
| Storage temperature range | 5 – 131 °F (-15 – 55 °C) |
| More details | |
| Remote management protocol | IPv4, TCP/IP, UDP, SNMPv1, HTTP, NTP, DNS, Telnet, DHCP, SMTP, FTP, IPv6, SNMPv3, HTTPs, SSH, SSL, TLS, LDAP(S), RADIUS, Syslog, CLI, Windows AD |
Questions about this item
What rack depth and clearance does the 1U PDU44006 need for its two 10 ft L6-20P input cords?
The unit occupies 1U of rack height; allow enough depth behind the rails for the 3.0 m cords to bend without sharp kinks and keep the rear vents clear for 0 – 45 °C airflow.
Which management protocol must be enabled first so the switched outlets respond to SNMPv3 commands?
Connect the RJ45 Ethernet port, assign a static IPv4 or DHCP address via the web UI, then enable SNMPv3 and create the user credentials before the C13 and C19 outlets will accept remote on/off cycles.
At what ambient temperature should the internal components be inspected for dust buildup on the PDU44006?
Inspect the inlet and outlet grilles every 6 – 12 months when operating near the 45 °C upper limit; clean with low-pressure air to maintain the 16 A derated capacity and UL62368 safety compliance.
More in Rackmount PDUs
Similar items
CyberPower PDU41023 PDU 16 Outlets 12 ft NEMA L5-30P 30A 100-120V
- Power Distribution…
CyberPower CPS1215RM 120V 15A Basic PDU 10 Outlets 15ft NEMA 5-15P 1U
- 1U
- 1U
Tripp Lite PDUNVR30HVLX Monitored PDU 24 Outlets 208/240V 5.8kW L6-30P
- Monitored
Tripp Lite PDUMV20 Metered PDU 20A 28 Outlets 120V 15ft 0U Vertical
- 0U
- 120 V
CyberPower PDU44004 Switched PDU 1U 200-240V 15A 10ft
- 1U
- 200–240 V