We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

CyberPower

CyberPower PDU44007 Switched ATS PDU 2U 30A 16×C13 2×C19 L6-30R

SKU CH-8DT0-G43JR MPN PDU44007

Switched 2U rack PDU with automatic transfer switching, 16 C13 and 2 C19 outlets, dual L6-30P inputs, and remote monitoring

  • Rack height2U
  • Supply voltage240 – 200 VAC
  • Input line frequency50 Hz – 60 Hz
  • Input current rating30A
  • Regulatory derated input current24 A
  • Input connection2 x NEMA L6-30P
  • Automatic transfer switching ensures continuous power supply
  • Sixteen C13 and two C19 outlets connect diverse rack equipment
  • Two NEMA L6-30P inputs provide redundant power feeds
  • Switchable outlets enable remote power cycling per device
  • Selectable colour LCD gives clear local status at a glance

Switched ATS PDU for rack power

The CyberPower PDU44007 is a switched automatic transfer switch power distribution unit built for 2U rackmount installations. It accepts dual 240–200 VAC feeds through two NEMA L6-30P plugs and delivers power through sixteen C13, two C19 and one L6-30R outlets. The unit is designed for data-centre and server-room environments that require redundant input sources and remote outlet control.

Replaces basic PDUs without transfer switching

This unit upgrades installations that rely on a single power feed or on non-switched distribution strips. The automatic transfer switch moves the load to the secondary source within milliseconds when the primary feed fails, while switchable outlets let administrators reboot individual devices remotely. The jump is worth it when uptime demands redundant inputs and when outlet-level power cycling reduces physical site visits.

Sustained load behaviour in 45 °C ambient

Dual 20 A branch breakers protect the outlet groups during continuous operation at the 24 A derated input rating. The selectable colour LCD reports real-time current, voltage and power factor per phase, and firmware upgrades can be applied without removing the unit from the rack. Operating temperature is rated up to 45 °C with non-condensing humidity to 95 %, so thermal headroom remains predictable under prolonged full-load conditions.

How it compares

Measured against everything we stock in Rackmount PDUs, at today’s prices. Recalculated every night.

Price $1,095.99
Pricier than about 78% of the 643 comparable items (median $451.99).

New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.

Specifications

Product
Brand nameCyberPower
Product lineSwitched ATS PDU
Model namePDU44007
Part numberPDU44007
Product typeSwitched
Design styleRackmount
Storage
Storage elevation0 – 49213 ft (0 – 14999 m)
Power
Supply voltage240 – 200 VAC
Input line frequency50 Hz – 60 Hz
Input current rating30A
Regulatory derated input current24 A
Input connection2 x NEMA L6-30P
Voltage output240 – 200 VAC
Output outlets16 – IEC-320 C13
2 – IEC-320 C19
1 – NEMA L6-30R
Overload protection20A x 2
Size & build
Rack height2U
Cord length10 ft (3.0 m)
Product dimensions17.05 × 3.5 × 8.45 (in)
Product weight17.6 lb (7.98 kg)
Shipping weight9.39 kg
Package size550 × 398 × 185 mm
Environment & compliance
Operating conditions32 – 113 °F (0 – 45 °C)
Operating humidity0 – 95 % (non-condensing)
Operating altitude0 – 13123 ft (0 – 4000 m)
Storage temperature range5 – 131 °F (-15 – 55 °C)

Questions about this item

What rack depth and clearance does the 17.05 x 3.5 x 8.45 inch 2U chassis require?

The unit fits a standard 19-inch rack with 2U height; allow at least 8.45 inches of depth behind the mounting rails plus cable bend radius for the 10 ft input cords.

How are the dual NEMA L6-30P input cords connected to enable automatic transfer switching?

Plug each L6-30P into separate 30 A 200–240 VAC circuits; the ATS logic then monitors both sources and transfers load within milliseconds when one fails.

When should the internal 20 A x 2 branch circuit breakers be inspected or replaced?

Check breaker operation annually or after any overload trip; replace a breaker that will not stay reset or shows discoloration, as the PDU has no user-serviceable fuses.

More in Rackmount PDUs