Dayton 1TDT4 Rectangular OEM Blower 1090 RPM 1 Phase Direct Drive Steel
Rectangular OEM blower delivers up to 805 cfm airflow at 1090 RPM with direct-drive steel construction
- Product typeHigh Temperature
- Delivers 805 cfm free airflow for strong ventilation
- Maintains 770 cfm at 0.100 in SP under light resistance
- Provides 711 cfm at 0.250 in SP for ducted runs
- Still moves 645 cfm at 0.400 in SP against higher pressure
- Direct-drive 1090 RPM motor eliminates belt wear
Rectangular OEM Blower 1090 RPM
This Dayton blower delivers 805 cfm at zero static pressure and maintains 605 cfm at 0.500 in SP. Direct-drive construction eliminates belt maintenance for continuous industrial airflow. Single-phase operation suits standard facility power.
Suited for ducted exhaust and make-up air
The forward-curved wheel handles elevated temperatures in drying ovens, fume hoods and heat-recovery ducts. Installations requiring variable-speed control or belt-drive serviceability should select a different configuration.
Assembled direct-drive package
The unit arrives fully assembled with the wheel mounted on the motor shaft. No separate drive components or field alignment are required, reducing commissioning time on replacement jobs.
How it compares
Measured against everything we stock in Indoor & Outdoor Ceiling Fans, at today’s prices. Recalculated every night.
- Price $226.99
- Pricier than about 79% of the 444 comparable items (median $99.99).
Specifications
| Product | |
|---|---|
| Brand name | Dayton |
| Product type | High Temperature |
Questions about this item
What electrical supply does the 1-phase Dayton 1TDT4 blower require?
The blower runs on single-phase mains voltage; confirm your supply matches the motor name-plate rating before wiring.
Will the 805 cfm at 0.000 in SP and 605 cfm at 0.500 in SP suit the ductwork I already have?
Compare your system curve to those two points; if your static pressure sits between them the fan will deliver the corresponding airflow.
How can I verify the blower is turning at 1090 RPM after installation?
Use a non-contact tachometer on the shaft or measure motor current against the name-plate full-load value to confirm rated speed.
More in Indoor & Outdoor Ceiling Fans
Similar items
Wiegmann Axial Ceiling Fan 10 in 115VAC 547 CFM 35 W 1650 RPM
- Round
Dayton 5JLP1 High Temperature Propeller 6 1/2 in 5 Blade White
- High Temperature
Dayton 5JLP6 High Temperature Propeller 7 in 5 Blade 1/4 in Bore White
- High Temperature
Dayton 4M262BG condenser fan motor 1/3 hp 825 RPM 208-230V
- High Temperature