Dayton 5UXL3 1 HP Convertible Jet Pump System 115/230V 17 gal Tank
Convertible jet pump system with 17.0 gal tank delivers up to 17.9 gpm at 30 psi and 1 hp on 115/230V power
- Product typeDrain Components
- 1 hp motor delivers strong water pressure
- Dual 115/230 V voltage fits standard wiring
- 17 gal tank stores water for steady flow
- Up to 17.9 gpm at 30 psi for high demand
- 80 ft max suction lift draws from deep sources
Pump system for residential water supply
The Dayton 5UXL3 is a convertible jet pump system rated at 1 hp for 115/230V AC operation. It includes a 17.0 gal tank with a 28 psi bladder pressure and is designed for household pressure boosting and shallow or deep well applications.
Pressure and lift limits define usable range
The pump delivers 17.9 gpm at 30 psi, 17.8 gpm at 40 psi and 17.2 gpm at 50 psi when lifting from 10 ft. Maximum suction lift is 80 ft, shut-off pressure is 75 psi and the maximum inlet pressure allowed is 123 psi. These figures set the practical envelope for installation planning.
Tank capacity and voltage must match the site
The 17.0 gal tank size and dual-voltage 115/230V motor are the primary specifications that determine whether this unit fits the available space and electrical supply. Inlet and discharge connections are 1 1/4 in NPT and 1 in NPT respectively.
How it compares
Measured against everything we stock in Drain Stoppers, Strainers & Traps, at today’s prices. Recalculated every night.
- Price $956.99
- Pricier than about 91% of the 4,240 comparable items (median $31.99).
Specifications
| Product | |
|---|---|
| Brand name | Dayton |
| Model name | 5UXL3 |
| Product type | Drain Components |
Questions about this item
How do I decide between the 115 V and 230 V wiring options for this 1 HP pump?
The motor draws 20 A at 115 V or 10.5 A at 230 V, so choose the voltage that matches your available circuit and wire gauge.
What flow can I expect at typical household pressure settings?
At 10 ft lift the pump delivers 17.9 gpm at 30 psi, 17.8 gpm at 40 psi and 17.2 gpm at 50 psi.
What does the 1 1/4 in NPT inlet and 1 in NPT discharge mean for my plumbing?
You will need 1 1/4 inch NPT pipe or fittings on the suction side and 1 inch NPT on the discharge side.
More in Drain Stoppers, Strainers & Traps
Similar items
Dayton 45MW18 Pressure Booster Pump 1 hp 120/240V 1 Phase 1-1/2 in NPT
Banjo RB300-150 3 inch MNPT x 1-1/2 inch FNPT Reducing Bushing Schedule 80 trap
Wheeler-Rex 39300 Hydrostatic Test Pump 4 gpm Twin Piston 3/4 in
- Drain Components