SAMSUNG 870 EVO 500 GB 2.5 inch SATA internal SSD
- ATA-6
- 2.5 in SATA III Int…
We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
Thermal overload relay protects motors at 0.40-0.63 A with auto or manual reset and IEC 60947-4-1 compliance
The Dayton 6ECA6 is a three-pole thermal overload relay designed for direct contactor mounting in industrial motor circuits. It operates within a current range of .40 to .63 A and carries IEC 60947-4-1, CSA and UL certifications. The unit features both automatic and manual reset options with a Trip Class 10 response.
This relay fits panels where a compact IEC-format device with 1NO/1NC auxiliary contacts is specified. It is not for applications that require a NEMA-rated frame, electronic trip units or current settings outside the .40-.63 A window. Buyers needing higher current ranges or different auxiliary configurations should look elsewhere.
Confirm that the contactor model accepts direct-mount IEC relays and that the .40-.63 A range matches the motor full-load current. The body measures 3.62 in deep, 1.85 in high and 1.73 in wide with an overall height of 2.5 in. Ensure the enclosure provides adequate clearance for wiring and the reset mechanism.
Measured against everything we stock in AV Accessories & Components, at today’s prices. Recalculated every night.
| Product | |
|---|---|
| Brand name | DAYTON |
| Product type | Industrial Electrical Controls & Automation |
| Product color | Transparent |
The relay uses a direct-to-contactor mounting style, so it attaches to a compatible IEC contactor without extra brackets.
Yes, the relay is rated Trip Class 10, matching the timing curve of older Class 10 starters in the same current band.
Apply load current above 0.63 A; the thermal element should open the NC contact and close the NO contact within the Class 10 time curve.
More in AV Accessories & Components
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?