Dayton Exhaust/Supply Fan 16 In 3 Phase
Direct-drive reversible ceiling fan with 16-inch blade diameter moves 2226 CFM exhaust or 1926 CFM supply at zero static pressure
- Product typeDirect Drive Reversible
- 16 in blade moves up to 2226 CFM exhaust airflow
- Direct drive reversible design handles both exhaust and supply needs
- 1/4 hp motor runs on 208-230/460V three-phase power
- Ball bearings and totally enclosed air-over enclosure suit 104°F ambient temps
- Galvanized steel frame measures 20x20x12 13/16 in for ceiling mounting
16-Inch Direct-Drive Reversible Ceiling Fan
This Dayton fan delivers reversible airflow for exhaust or supply duties in commercial and industrial spaces. The direct-drive design eliminates belts and pulleys, reducing maintenance while the galvanized frame resists corrosion in damp environments. Ball bearings and a totally enclosed air-over motor support continuous operation at ambient temperatures up to 104 degrees F. Suitable for facilities needing reliable air movement without belt adjustments.
Three-Phase Voltage and Static-Pressure Limits
The motor runs on 208-230/460 V AC three-phase power, drawing 1.5-1.6 or 0.9 operating amps depending on wiring. At zero static pressure it moves 2226 CFM exhaust or 1926 CFM supply; at 0.250 in. SP output drops to 1654 CFM exhaust and 1420 CFM supply. RPM varies between 1750 and 1742 across the voltage range. Installations requiring higher static pressure or single-phase power cannot use this unit.
Quarter-Horsepower Motor Determines Fit
The 1/4 hp motor sets the airflow ceiling for this 16-inch blade diameter. Buyers needing greater CFM at the same static pressure must select a larger-horsepower model, as this frame and blade combination cannot exceed the rated performance. The fixed 20-by-20-inch frame with 12 13/16-inch depth also limits retrofit options where mounting clearances are tighter.
How it compares
Measured against everything we stock in Indoor & Outdoor Ceiling Fans, at today’s prices. Recalculated every night.
- Price $564.99
- Pricier than about 91% of the 444 comparable items (median $99.99).
Specifications
| Product | |
|---|---|
| Brand name | Dayton |
| Product type | Direct Drive Reversible |
Questions about this item
Should I pick the 208-230V or 460V wiring for this 1/4 hp fan?
The motor runs on either 208-230V AC at 1.5-1.6 amps or 460V AC at 0.9 amps; choose the voltage that matches your three-phase supply.
What airflow will I actually get at 0.250 in. static pressure?
Expect 1654 CFM exhaust or 1420 CFM supply at 0.250 in. SP, well below the free-air ratings of 2226/1926 CFM.
How does the three-phase input affect installation?
You need a 208-230/460V three-phase circuit; the fan draws 1.5-1.6A at low voltage or 0.9A at high voltage and runs at 1750/1742 RPM.