Dayton GGS_47824 1 hp Direct Drive Blower Motor
A 1 hp permanent split capacitor motor running at 115 V AC and 1100 RPM for HVAC blowers
- Product typeMotors
- 1 hp single-phase motor delivers strong airflow
- 1,100 RPM nameplate speed provides consistent circulation
- Auto thermal protection prevents overheating damage
- Totally enclosed air-over enclosure resists dust and moisture
- Continuous duty cycle supports non-stop HVAC operation
Direct-Drive HVAC Blower Motor
This 1 hp Dayton motor is built for definite-purpose HVAC installations that require a permanent-split-capacitor design. It suits technicians and facility managers who need a single-speed replacement for air-handling equipment running on 115 V AC.
Single-Phase 115 V Integration
The motor draws 10 A at full load and operates on a 60 Hz supply, so the circuit must provide that voltage and frequency. Its non-standard frame means mounting dimensions must be verified against the existing housing before installation. Continuous duty rating allows it to run without intermittent rest periods.
Sustained Operation at 40 °C Ambient
Thermal protection is automatic and the insulation class B rating supports a maximum ambient temperature of 40 °C. Nameplate speed is 1 100 RPM under continuous load, and the shaft rotates clockwise when viewed from the shaft end. The motor is not usable at 200 V or 208 V, so voltage must remain at the rated 115 V.
How it compares
Measured against everything we stock in Indoor & Outdoor Ceiling Fans, at today’s prices. Recalculated every night.
- Price $308.99
- Pricier than about 85% of the 444 comparable items (median $99.99).
Specifications
| Product | |
|---|---|
| Brand name | DAYTON |
| Product type | Motors |
Questions about this item
Does the 1 hp motor run continuously without overheating in a 40 °C ambient?
Yes, the motor is rated for continuous duty with Class B insulation and automatic thermal protection up to a maximum ambient temperature of 40 °C.
How much current does the motor draw at full load on a 115 V supply?
The nameplate shows 10 A at full load on 115 V AC, 60 Hz single phase.
What shaft rotation and mounting frame should the existing equipment have for a direct swap?
The motor has a clockwise shaft-end rotation and a non-standard frame; it replaces Dayton 1LXN4D.