Eaton EMA333-10 Managed PDU 28-Outlets 8.64 kVA 120/230 V
Rack-mountable managed PDU distributes 8.64 kVA across 28 outlets including 21 C13, six C19 and one NEMA 5-20R
- Supply voltage120 V AC 230 V AC
- Product typeOthers
- Key featuresPower Rating:8.64 kVA Form Factor:Rack-mountable Product Typ
- Managed power monitoring for 28 outlets
- 64 kVA capacity supports dense rack deployments
- Dual 120 V and 230 V input compatibility
- NEMA L21-30P input with mixed IEC C13 and C19 outputs
- Rack-mountable form factor simplifies data-centre integration
Managed PDU with 28 outlets
The Eaton EMA333-10 is a rack-mountable managed power distribution unit delivering 8.64 kVA. It accepts 120 V AC or 230 V AC input through a NEMA L21-30P plug. The unit provides 28 output receptacles: one NEMA 5-20R, twenty-one IEC 60320 C13 and six IEC 60320 C19 sockets. Remote monitoring and outlet-level control are supported via the managed series platform.
Rack deployments needing dense monitored power
This PDU suits data-centre racks and server rooms that require single-phase or split-phase input with a high outlet count and per-outlet metering. It fits standard 19-inch cabinets and supports environments where capacity planning and remote reboot capability matter. Buyers who need only basic power distribution without network management should consider simpler strip models. Facilities lacking a NEMA L21-30P source or requiring three-phase input will need a different unit.
8.64 kVA rating and NEMA L21-30P input
The 8.64 kVA power rating determines the maximum connected load the PDU can support. The NEMA L21-30P input plug requires a matching 30 A branch circuit and receptacle on the upstream UPS or panel. Verify that your facility provides this exact connection before purchase.
How it compares
Measured against everything we stock in Rackmount PDUs, at today’s prices. Recalculated every night.
- Price $1,610.99
- Pricier than about 90% of the 643 comparable items (median $451.99).
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Specifications
| Product | |
|---|---|
| Brand name | Eaton |
| Product line | Managed |
| Product type | Others |
| Power | |
| Supply voltage | 120 V AC 230 V AC |
| Size & build | |
| Shipping weight | 9.21 kg |
| Package size | 2040 × 2040 × 236 mm |
Questions about this item
What does the 8.64 kVA rating mean for equipment I can connect?
The 8.64 kVA rating indicates the maximum apparent power the PDU can distribute across its 28 outlets without overloading the NEMA L21-30P input.
What does the NEMA L21-30P input cap in practice?
The NEMA L21-30P input limits the PDU to a 30 A three-phase supply at 120/230 V AC, defining the total power available to all outlets.
What rack space does this 28-outlet PDU need to mount?
The rack-mountable form factor fits a standard 19-inch rack, using the included brackets for horizontal or vertical installation depending on the model length.
More in Rackmount PDUs
Similar items
CyberPower CPS1215RM 120V 15A Basic PDU 10 Outlets 15ft NEMA 5-15P 1U
- 1U
- 1U
APC AP7968B Switched PDU 0U 208V 35A 21 C13 3 C19
- 0U
- cUL Listed, CSA, FC…
Tripp Lite PDUMV20 Metered PDU 20A 28 Outlets 120V 15ft 0U Vertical
- 0U
- 120 V
APC AP8659 PDU 20A 208V 16A 230V 21xC13 3xC19 ZeroU
- 200 V AC, 208 V AC,…
- Others