We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
A bimetallic thermal overload unit rated 26.50–28.50 A, Trip Class 20, for NEMA Size 2 starters
The Eaton FH53 is a bimetallic thermal unit rated for a full-load current range of 26.50 to 28.50 amperes. It provides overload protection for NEMA Size 2 motor starters in industrial control panels. The transparent housing allows visual inspection of the trip mechanism. It is designed for use with Series A200 and B100 starters.
This unit operates on Trip Class 20 timing, meaning it will trip within a defined period under sustained overload conditions to protect motor windings. The bimetallic element responds to heat generated by excessive current. No separate accessories or software are included; the unit functions as a direct replacement component. Compatibility is defined by the starter model series.
Electrical technicians servicing compatible Eaton Cutler-Hammer starters can install this unit to restore overload protection. It suits panels where the motor full-load current falls within the 28.8 to 31.4 or 33.4 to 36.4 ampere ranges. Installers working with different NEMA sizes or non-compatible starter series must select an alternative thermal unit.
Measured against everything we stock in AV Accessories & Components, at today’s prices. Recalculated every night.
| Product | |
|---|---|
| Brand name | Eaton |
| Model name | FH53 |
| Product type | Bimetallic |
| Product color | Transparent |
The FH53 is a bimetallic thermal unit rated for Trip Class 20 overload protection. It operates on a calibrated trip curve rather than a fixed service interval. Replacement is only required after a trip event or if the unit shows physical damage or calibration drift.
The FH53 covers a full-load current range of 28.8 to 31.4 A and 33.4 to 36.4 A. Sustained current above the upper end of the selected range will cause the bimetallic element to trip in accordance with its Trip Class 20 time-current characteristic.
The bimetallic element generates heat proportional to the square of the load current. At the top of its 33.4 to 36.4 A range the unit dissipates several watts, so panel ventilation must be sized to remove that heat and keep ambient temperature within the starter's rating.
More in AV Accessories & Components
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?