We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
Thermal overload unit for NEMA motor starters, adjustable 1.79 to 2.9 A trip range, Trip Class 20, pack of three
The Eaton H2006B-3 thermal unit provides overload protection for motor starters in industrial electrical control systems. It covers a full-load current range of 1.79 to 2.9 A and carries a Trip Class 20 rating. The pack contains three identical units for multi-starter installations.
Each unit uses a thermal overload mechanism calibrated for Trip Class 20 response. Under typical operating currents the element remains stable and dissipates heat without nuisance tripping. The transparent housing allows visual inspection of the internal components during routine checks.
When current exceeds the set range continuously the thermal element heats progressively and opens the control circuit within the Class 20 time curve. This protects downstream wiring and motor windings from prolonged overload conditions. The units are compatible with NEMA sizes 0, 00, 1, 2, 5, 6, 7, 8 and Series Freedom frames G through Z.
Measured against everything we stock in AV Accessories & Components, at today’s prices. Recalculated every night.
| Product | |
|---|---|
| Brand name | Eaton |
| Product type | Industrial Electrical Controls & Automation |
| Product color | Transparent |
Snap the unit into the overload relay base matching the NEMA size label; the step often missed is verifying the frame-size letter (G through Z) on the starter matches the unit before locking it in.
The thermal element is non-repairable; after any overload trip or if the 1.79 to 2.9 A calibration drifts, replace the entire unit — keep the spare two from the pack for quick change-out.
Trip Class 20 defines the limit: the unit must open within 20 seconds at six times the 2.9 A maximum rating, so sustained overcurrent hits the thermal trip curve before any other threshold.
More in AV Accessories & Components
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?