We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
12 V DC solenoid rated for 150 A continuous duty with silver-alloy contacts and isolated coil
This 12 V DC power solenoid from White-Rodgers is rated for 150 A continuous duty. It uses an SPST-NO contact form with silver alloy contacts and a standard mounting bracket. The unit suits industrial electrical control and automation circuits that require reliable high-current switching.
The coil resistance is 13.2 ohm at 12 V, drawing modest power during continuous operation. Maximum operating temperature reaches 149 degrees F while the minimum is -40 degrees F. The isolated coil design helps contain heat within the solenoid body.
Contact termination uses a 5/16 in-24 UNF-2A thread and coil termination uses a #10-32 UNF-2A thread, providing four terminals in total. Overall length is 3.56 in and height is 2.19 in, allowing the solenoid to fit standard brackets without extra clearance.
Measured against everything we stock in AV Accessories & Components, at today’s prices. Recalculated every night.
| Product | |
|---|---|
| Brand name | White-Rodgers |
| Model name | 124-105111 |
| Product type | Industrial Electrical Controls & Automation |
| Product color | Transparent |
Torque the 5/16 in-24 UNF-2A contact terminals to the manufacturer spec for 150 A DC and the #10-32 UNF-2A coil terminals for 12 V DC. The isolated coil means coil circuit shares no path with the contact circuit, so keep wiring separate. The step people miss is verifying polarity on the coil terminals before energising.
Inspect the silver-alloy contacts for pitting or carbon build-up after high-cycle use; replace the solenoid if contact resistance rises or the 13.2 ohm coil reads open or shorted. Continuous duty at 150 A accelerates wear, so schedule checks based on cycle count rather than calendar time.
The 149 °F maximum operating temperature is the first hard limit; sustained 150 A in a confined space can push the housing past that point, causing the coil resistance to drift and the contact spring to lose force. Mount on the standard bracket with airflow and monitor case temperature.
More in AV Accessories & Components
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?