We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Emerson Climate Technologies

Emerson Climate Technologies 90-246 Contactor 2 Pole 208/240VAC 30 Amps

SKU CH-H464-SN01H

A 2-pole definite-purpose magnetic contactor rated 30 A inductive and 40 A resistive at 208/240 VAC, 50/60 Hz, with CE and CSA standards

  • Reliable motor control with 30 A inductive rating
  • Handles resistive loads up to 40 A for heating circuits
  • Operates on 50/60 Hz at 208/240 VAC
  • Compact 2.45 in height fits tight panels

Definite Purpose 2-Pole Contactor

The WHITE-RODGERS 90-246 is a definite purpose magnetic contactor rated for 208/240 VAC operation. It provides two poles and handles 30 A full load inductive or 40 A resistive current. This component suits HVAC and machinery controls where a compact starter is required. It is not for applications needing an enclosed housing or reversing function.

Thermals Noise And Power Draw

The open-frame design relies on natural convection, so no fan noise is produced during normal use. Coil power draw follows standard 50/60 Hz contactor levels for this frame size. The unit meets CE and CSA standards for safe temperature rise. Installers must provide adequate airflow in the enclosure to maintain rated performance.

How it compares

Measured against everything we stock in Contactors, Relays & Motor Starters, at today’s prices. Recalculated every night.

Price $10.99
Cheaper than about 91% of the 1,098 comparable items (median $61.99).

Specifications

Product
Brand nameWHITE-RODGERS

Questions about this item

How do I mount the 90-246 contactor and what wiring step is often missed?

Mount the unit using its 2.45 in height, 2 in width and 3.31 in depth footprint; the step often missed is confirming the coil is rated for 208/240 VAC at 50/60 Hz before connecting control wires.

Which parts of the 90-246 contactor will need replacement first under a 30 A inductive load?

The main contacts are the wear items; at 30 A full-load inductive rating they will eventually pit and require the contactor to be swapped out.

More in Contactors, Relays & Motor Starters