FASCO A086 Induced Draft Furnace Blower 115V AC 1.3A 60Hz
Induced draft furnace blower for natural-gas furnaces, 115 V AC, 1.3 A, 60 Hz, 3,200 RPM motor speed, replaces Rheem and Ruud models 70215990 and 703020
- Delivers 115 V AC power for reliable furnace operation
- Shaded-pole motor rated at 1.3 A for efficient airflow
- Spins up to 3 400 RPM for strong induced draft
- Directly replaces Rheem/RUUD part numbers 70215990 and 703020
- Class B insulation supports continuous 60 Hz duty
Direct replacement for Rheem and Ruud gas furnaces
This FASCO A086 induced draft blower is a direct replacement for Rheem and Ruud gas furnaces using manufacturer model numbers 70215990 and 703020. It runs on 115 V AC single-phase power at 60 Hz and draws 1.3 A. The shaded-pole motor is rated for insulation class B and delivers a maximum fan speed of 3,400 RPM with a motor speed of 3,200 RPM. Wire leads provide the electrical connection.
Suits installers matching the exact part numbers
Technicians who need a 115 V AC induced draft blower with a 3 inch inlet and 2 1/2 inch outlet for the listed Rheem and Ruud models can use this unit. Installers working on furnaces that call for a different voltage, fuel type, or manufacturer part number should look at other models.
115 V AC nameplate voltage at 60 Hz
The single specification that determines fit is the nameplate voltage of 115 V AC at 60 Hz single-phase. If the furnace requires a different supply voltage or frequency, this blower will not operate correctly.
How it compares
Measured against everything we stock in Heating & Cooling Controllers, at today’s prices. Recalculated every night.
- Price $157.99
- Pricier than about 77% of the 1,762 comparable items (median $45.99).
Specifications
| Product | |
|---|---|
| Brand name | FASCO |
Questions about this item
What 115 V AC frequency does the FASCO A086 blower require?
It runs on 60 Hz single-phase power, drawing 1.3 A at nameplate voltage.
Which furnace models does the 3 in inlet and 2 1/2 in outlet fit?
Direct replacement for Rheem and RUUD units using manufacturer numbers 70215990 and 703020.
How do you wire the shaded-pole motor correctly?
Connect the two wire leads to 115 V AC line and neutral; the motor has no capacitor, so polarity does not matter.
More in Heating & Cooling Controllers
Similar items
Tempco CSF00110 Fin Strip Heater 240V 450W 35 7/8 in 1200 Deg F hvac control
Tempco TEC16001 Temperature Controller 90-250V Relay 2A 1/16 DIN hvac control
- Transparent
Ductmate GRDOI1612GA Observation Access Door hvac control