FASCO A213 Draft Inducer 115V HVAC Control
A 115 V draft inducer for furnaces with a 2 in inlet and outlet, shaded-pole motor at 3 200 RPM max, 2.1 A draw, and Lennox 18L0401 compatibility
- Delivers reliable furnace draft with 115V shaded-pole motor
- Replaces Lennox 18L0401 and 702110376 for exact fit
- Operates at 3,200 RPM fan speed for strong airflow
- Runs on 2.1 A current at 60 Hz single phase
- Withstands inlet air up to 40 °C for durability
FASCO A213 Draft Inducer for Lennox Furnaces
This FASCO A213 draft inducer replaces Lennox part numbers 18L0401 and 702110376 on residential furnaces. It operates on 115V AC single-phase power at 60 Hz and draws 2.1 A through wire leads. The shaded-pole motor is rated for Class B insulation.
Thermals, Noise and Power in Normal Use
The motor reaches a maximum speed of 3,200 RPM with a fan speed up to 3,400 RPM during standard operation. Inlet air temperature must not exceed 40 degrees C. Static pressure capability tops out at 3 1/4 in wc. The unit uses a shaded-pole motor design with Class B insulation for reliable continuous duty.
Behaviour Under Sustained Load
Under prolonged heating cycles the shaded-pole motor maintains its rated 3,200 RPM maximum speed within the 40 degrees C inlet limit. Current draw remains at the nameplate 2.1 A at 115V AC. The 2 in inlet and outlet diameters maintain airflow without restriction. This inducer is not suited for appliances requiring higher static pressure or different voltage.
How it compares
Measured against everything we stock in Heating & Cooling Controllers, at today’s prices. Recalculated every night.
- Price $193.99
- Pricier than about 81% of the 1,762 comparable items (median $45.99).
Specifications
| Product | |
|---|---|
| Brand name | FASCO |
Questions about this item
How do I wire the 115V shaded-pole motor to the furnace control board?
Connect the two wire leads to the inducer terminals on the board; the motor is single-phase so polarity does not matter, but secure the ground screw to the chassis before restoring power.
When should I plan to replace the motor bearings on this draft inducer?
The shaded-pole motor uses sleeve bearings rated for continuous operation at 40 °C inlet air; expect service intervals of several heating seasons and replace when fan speed drops below 3 200 RPM or noise increases.
What static-pressure limit will trip the pressure switch first during a long heating cycle?
The inducer is rated for a maximum of 3 1/4 in wc; if vent restriction or a dirty heat exchanger pushes static pressure above that value the pressure switch will open and shut down the furnace.
More in Heating & Cooling Controllers