Fernco Inc. 3000-33 Shielded Coupling 3 In
Connects 3-inch cast-iron to plastic or steel DWV pipe with an internal stop, shear ring and clamps meeting ASTM A167-91, rated to 4.3 psi and 180 °F
- Product typeDrain Components
- Main materialElastomeric PVC
- Connects cast-iron to plastic or steel without bushings
- Internal pipe stop ensures correct fit and cuts noise
- Stainless-steel shear ring and clamps meet ASTM A167-91
- Withstands 180 °F operating temperature for DWV systems
- Tested to 4.3 psi and installs at 60 in-lb torque
3-Inch Shielded Coupling for DWV Systems
This Fernco shielded coupling joins 3-inch cast-iron pipe to plastic, steel or extra-heavy cast iron without bushings. An internal pipe stop aligns the joint during assembly and dampens vibration. The elastomeric PVC sleeve and stainless-steel clamp meet ASTM A167-91 requirements for drain-waste-vent installations.
Tested to 4.3 psi at 180 F operating temperature
The coupling withstands 4.3 psi test pressure while handling continuous flow up to 180 F. Clamp torque is set at 60 in-lb to maintain a secure seal without over-tightening the elastomeric sleeve. This combination keeps the joint leak-free under normal DWV pressure and thermal cycling.
Replaces bushing-dependent transitions on 3-inch
Use this coupling when converting existing cast-iron stacks to modern plastic or steel piping without adding separate bushings. The integrated stop and shear ring simplify the retrofit and reduce potential leak paths. Not suited for pressure-rated supply lines or sizes other than the listed 3-inch by 3-inch configuration.
How it compares
Measured against everything we stock in Drain Stoppers, Strainers & Traps, at today’s prices. Recalculated every night.
- Price $7.99
- Cheaper than about 88% of the 4,240 comparable items (median $31.99).
Specifications
| Product | |
|---|---|
| Brand name | Fernco |
| Product type | Drain Components |
| Size & build | |
| Main material | Elastomeric PVC |
Questions about this item
How do I install the Fernco 3000-33 shielded coupling and what torque mistake should I avoid?
Slide the coupling over the prepared pipe ends until each reaches the internal stop, then tighten the clamp assemblies to exactly 60 In./Lb. using a calibrated torque wrench; over-tightening can distort the elastomeric PVC sleeve and compromise the seal.
What maintenance or replacement will the Fernco 3000-33 coupling need over time?
Inspect the elastomeric PVC body and stainless clamp assemblies periodically for cracking, corrosion, or loss of elasticity; replace the entire coupling if the material hardens, the shear ring deforms, or leakage appears at the joint.
What is the first performance limit the Fernco 3000-33 coupling reaches under sustained DWV service?
The 4.3 psi test pressure rating is the primary limit; sustained internal pressure above this level can overcome the clamp preload and cause joint separation before temperature or torque limits are reached.
More in Drain Stoppers, Strainers & Traps
Similar items
360EXPRESS DCS-2P drain sticks 24 pack
- DCS-2P, 360EXPRESS
- Breaks down clogs a…
Fernco Inc. QC-105 PVC Trap 5 in 4.3 psi 140°F
- Drain Components
- HAWA