Fluke 750P09 Gage Pressure Module 0-1500 psi 0-100 bar 0-10 MPa
Gauge pressure module measures 0-1500 psi with 3X burst rating and digital communication to Fluke 725, 726, 750 Series calibrators
- Product typeElectronic
- Measures up to 1500 psi, 100 bar, or 10 MPa
- 3X burst rating protects against overpressure spikes
- Digital link to calibrators avoids analog errors
- Swaps between 725, 726, or 750 calibrators without recalibration
- Displays pressure in up to 11 engineering units
Pressure range and compatibility
The Fluke 750P09 is a gauge pressure module covering 0 to 1500 psi, 0 to 100 bar and 0 to 10 MPa. It connects directly to Fluke 725, 726 and 750 series calibrators, turning them into pressure calibrators without analog losses.
Digital communication and burst rating
The module transmits measurements digitally to the calibrator, eliminating analog errors in normal use. A burst rating of 3X provides a structural safety margin above the 1500 psi upper limit.
Independent calibration and quick connectors
Each module is calibrated independently, so it can be moved between compatible calibrators without losing accuracy or traceability. Tool-free connectors allow fast, wrench-free attachment to a pressure source or hand pump, and the calibrator displays results in up to 11 engineering units at the push of a button.
How it compares
Measured against everything we stock in Meters, Testers & Measuring Tools, at today’s prices. Recalculated every night.
- Price $2,047.99
- Pricier than about 93% of the 3,030 comparable items (median $54.99).
Specifications
| Product | |
|---|---|
| Brand name | FLUKE |
| Product type | Electronic |
Questions about this item
How do I install the 750P09 module on a 725 or 726 calibrator and what step is often missed?
Connect the module to the pressure source or hand pump, attach the module cable to the calibrator, then apply pressure. The step often missed is selecting the correct engineering unit on the calibrator before recording data.
What maintenance or replacement will the 750P09 need over time?
The module is independently calibrated, so it requires periodic recalibration to maintain traceability. No user-serviceable parts are described; follow Fluke's recalibration schedule for the 0-1500 psi range.
What limit appears first during sustained use at the top of the 1500 psi range?
The burst rating is 3X the 1500 psi upper limit, so over-pressure protection is the primary safety boundary. Sustained operation at full scale stays within the calibrated range; no thermal or duty-cycle limit is specified.
More in Meters, Testers & Measuring Tools