Fluke 922 Kit Handheld Micromanometer 0 to 16 in WC
Measures air pressure, velocity and flow up to 16 in WC with ±1.00 % pressure accuracy and ±2.50 % velocity accuracy at 2000 fpm
- Measures pressure from 0 to 16 in WC with ±1.00 % accuracy
- Reads air velocity up to 16,000 fpm with ±2.50 % accuracy at 2000 fpm
- Calculates airflow up to 99,999 cfm, cu m/hr or L/sec
- Five-digit LCD display shows clear readings in cfm, fpm or Pa
- Kit includes batteries for immediate use
What the Fluke 922 Kit Measures
The Fluke 922 Kit is a handheld micromanometer designed for HVAC technicians and facilities engineers who need to verify low-pressure air systems. It reads differential pressure from 0 to 16 in WC and calculates air velocity up to 16,000 fpm and volume up to 99,999 cfm. The 5-digit LCD shows results in cfm, fpm or Pa for quick on-site analysis.
Kit Contents and Immediate Use
The kit ships with batteries installed so the instrument is ready for the first measurement session. Two hose-barb sizes, 1/8 in and 3/16 in, are included to match common tubing without extra adapters. Wireless connectivity is absent, so all readings remain on the local display and must be recorded manually by the operator.
Pre-Purchase Compatibility Checks
Verify that the process connections on your ductwork or test ports accept 1/8 in or 3/16 in hose barbs before ordering. Confirm the expected pressure range stays within 0 to 16 in WC and that the required accuracy of +/- 1.00 percent pressure and +/- 2.50 percent velocity at 2000 fpm meets your test standard. The unit has no wireless output, so plan for manual data logging if your workflow requires digital transfer.
How it compares
Measured against everything we stock in Meters, Testers & Measuring Tools, at today’s prices. Recalculated every night.
- Price $711.99
- Pricier than about 91% of the 3,030 comparable items (median $54.99).
Specifications
| Product | |
|---|---|
| Brand name | FLUKE |
Questions about this item
Will the pitot tube or hose connections need periodic replacement?
The kit uses 1/8 in and 3/16 in hose barb fittings; the tubing can be swapped if it cracks or kinks, and the pitot tube itself is stainless steel so it rarely needs changing unless bent.
What limits continuous logging at the top of the 16 in WC range?
The sensor is rated to ±1.00 % accuracy up to 16 in WC; sustained pressure at that ceiling will not damage the unit but accuracy is only guaranteed within the stated range.
How much heat or noise does the 922 produce during all-day use?
The handheld has no fan or moving parts, runs on the included batteries and generates no audible noise or noticeable heat even during extended logging sessions.
More in Meters, Testers & Measuring Tools
Similar items
FLUKE networks VISIFAULT Visual Fault Locator 2.5mm Adapter
- Test Lead Kits
InfiRay T3 Pro Mini Thermal Imager Android Type-C 25Hz 384x288
- Mini Thermal Scope…
- Thermal Camera