GE 60 A 240 V AC Non-Fusible Disconnect Switch DPST NEMA 3R
Non-fusible DPST disconnect rated 60 A at 240 V AC, NEMA 3R enclosure with pull-out design, cUL and UL listed
- Product typeIndustrial Electrical Controls & Automation
- 60 A rating handles heavy-duty AC loads
- 10 hp at 240 V AC powers demanding motors
- NEMA 3R enclosure protects against rain and sleet
- Non-fusible pull-out design simplifies maintenance
- cUL and UL listed for code compliance
60 A 240 V AC Non-Fusible Disconnect
This 60-ampere non-fusible disconnect switch uses a DPST contact form for single-phase 240 V AC circuits. It carries a 10 hp rating at 240 V and a NEMA 3R enclosure for outdoor or damp locations. The pull-out design provides visible isolation for air-conditioning or motor loads.
Check Voltage Phase And Enclosure Rating
Verify that the supply is single-phase 240 V AC and that a NEMA 3R rating satisfies the installation environment. Confirm the circuit requires a two-pole two-wire disconnect with a 60 A current rating. Ensure local code accepts a non-fusible switch without integral overcurrent protection.
Pull-Out Mechanism And cUL UL Listings
The pull-out handle gives a clear visual break and simplifies lockout-tagout procedures. cUL and UL listings confirm compliance with North American safety standards for industrial control equipment. The plastic housing resists corrosion in the NEMA 3R enclosure.
How it compares
Measured against everything we stock in Electrical Switches & Dimmers, at today’s prices. Recalculated every night.
- Price $36.99
- Typical for this category: the median of 791 items is $39.99.
Specifications
| Product | |
|---|---|
| Brand name | MIDWEST |
| Product type | Industrial Electrical Controls & Automation |
Questions about this item
Does the GE 60 A disconnect switch include mounting hardware or pull-out handle, or must they be purchased separately?
The switch ships as a complete unit with its pull-out handle and plastic NEMA 3R enclosure; mounting screws are not supplied and must be sourced separately.
Should I choose the 60 A 10 hp version or a lower-amp model for a 240 V single-phase air-conditioning circuit?
Select the 60 A 10 hp rating when the compressor nameplate shows full-load amps up to 60 A; a lower-amp model would not carry the required load.
What does the 60 A rating mean when the switch is installed in a real 240 V AC condenser circuit?
It indicates the switch can continuously carry 60 A and safely interrupt a 10 hp single-phase motor load at 240 V AC without a fuse.
More in Electrical Switches & Dimmers
Similar items
Hubbell Incorporated HBL8300SGA Straight Blade Receptacle 5-20R 20A
- Brown
- Wiring Devices
Leviton Manufacturing Co. 052-10097-008 pull chain switch
Hubbell Incorporated HBL8200SGRA Duplex Straight Blade Receptacle
- Red
- Wiring Devices
Schneider Electric 9001KR2G 30mm green push button
- Green
- Light Switch