We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
Two-pack of MQ-2 modules detecting smoke, LPG, butane and hydrogen with digital and analogue outputs at 5 V
This pack contains two MQ-2 sensor modules designed to detect combustible gases including smoke, LPG, butane and hydrogen. Each module operates on a 5 V DC supply drawing 150 mA and provides both a TTL digital output and an analogue voltage output proportional to gas concentration. The sensors require roughly 20 seconds to warm up before readings stabilise.
These modules suit hobbyists and engineers building gas-leak alarms, ventilation triggers or air-quality monitors for indoor use. The analogue output allows threshold tuning while the digital pin gives a simple high-low signal for microcontroller interrupts. Buyers needing calibrated ppm accuracy, multi-gas selectivity or industrial certifications should look at professional instrumentation instead.
The key specification is the combined TTL digital and 0.1–4 V analogue interface that lets a single module drive both a microcontroller GPIO and an ADC channel. If your design only accepts I²C, SPI or a dedicated gas-sensor bus, these boards will not connect without extra circuitry.
Measured against everything we stock in Sensors, Buzzers & Control Modules, at today’s prices. Recalculated every night.
| Product | |
|---|---|
| Model name | MQ-2 |
| Item name | HUABAN MQ-2 |
| Lighting type | Visual |
| Design style | Contemporary |
| Size & build | |
| Overall size | 0.79 in × 1.26 in × 0.76 in |
| More details | |
| Placement and use | Simple |
| Team affiliation | 2 Piece |
Connect VCC to 5 V DC, GND to ground, then read the digital DO pin for a TTL 0/1 signal or the analogue AO pin for 0.1–0.3 V rising to about 4 V at maximum concentration. The step most people miss is allowing the sensor to warm up for around 20 s after power is applied before trusting any reading.
The tin-oxide sensing layer inside the module gradually loses sensitivity after long exposure to combustible gases such as LPG, butane or hydrogen, so the whole module is replaced when calibration can no longer bring readings back into range.
The internal heating wire that keeps the sensing element at temperature draws 150 mA at 5 V; during sustained use the module becomes warm, and if it gets hot rather than just warm the readings become unstable and the sensor must be power-cycled.
More in Sensors, Buzzers & Control Modules
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?