SAMSUNG Atlas Sound AT-100 100W Commercial Attenuator video accessory
- Hard Wire Dimmer
- Black
We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
A hard-wired 240 V GFCI rated for 30 A with a Valox enclosure rated 4X for panel or surface mounting
This hard-wired ground-fault circuit interrupter is rated for 30 A at 240 V AC single phase. It is intended for panel or surface mounting in locations that require personnel protection on 240 V branch circuits. The enclosure carries a 4X rating and is moulded from Valox material. A 3/4 in NPT inlet accepts standard conduit entries.
The device operates from -30 °F to 150 °F without an audible alert, so it adds no noise in normal service. Power draw is limited to the sensing and trip circuitry inside the 4X enclosure. Manual reset ensures the circuit stays open until a deliberate restart after a fault.
When a ground fault persists the breaker trips and remains open until the manual reset is actuated, preventing automatic re-energisation of a faulty circuit. The Valox housing and 4X rating maintain integrity during repeated fault events across the full temperature span. The two-foot lead length provides adequate reach for panel wiring.
Measured against everything we stock in AV Accessories & Components, at today’s prices. Recalculated every night.
| Product | |
|---|---|
| Brand name | Hubbell Wiring Device-Kellems |
| Model name | GFHW23005 |
| Product type | Hard Wired |
| Product color | Black |
Mount the enclosure on a panel or surface, connect line and load conductors to the internal terminals, and secure the 3/4 in NPT inlet; the step often missed is torquing the terminal screws to the listed value so the 30 A rating is maintained.
Test the manual reset button monthly; if the device trips and will not reset, or the Valox enclosure shows UV cracking after prolonged exposure, replace the entire unit — no internal parts are serviceable.
The 150 °F maximum operating temperature is the first boundary reached; sustained 30 A operation in a sealed 4X enclosure can push internal temperatures to that limit before the GFCI trips.
More in AV Accessories & Components
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?