Ideal 61-176 Isolated Ground Adapter measurement tool
Isolated ground adapter compatible with SureTest circuit analyzers models 61-164 and 61-165, includes cord with NEMA 5-20 plug configuration
- Product typeAssortments & Kits
- Isolated ground testing protects sensitive equipment
- Compatible with SureTest circuit analyzers models 61-164 and 61-165
- NEMA 5-20 plug fits 20-amp circuits
- White polyethylene housing resists impact and chemicals
- Includes cord for immediate connection to testers
Ideal 61-176 Isolated Ground Adapter
The Ideal 61-176 is an isolated ground adapter built for electrical testing environments. It connects directly to compatible circuit analyzers to provide a secure ground reference during measurements. The adapter includes a cord and features a NEMA 5-20 plug configuration. Its white polyethylene housing suits professional field use.
Compatible SureTest analyser users
This adapter suits technicians operating Ideal SureTest circuit analysers such as the 61-164 or 61-165 models. It is not intended for general-purpose outlet testing or for use with analysers outside the specified series. Users needing a different plug configuration or a standalone tester should look at other equipment.
NEMA 5-20 plug configuration
The single specification that decides fit is the NEMA 5-20 plug configuration on the included cord. The adapter only functions when the circuit analyser and the supply receptacle both match this exact connector type.
How it compares
Measured against everything we stock in Meters, Testers & Measuring Tools, at today’s prices. Recalculated every night.
- Price $23.99
- Cheaper than about 73% of the 3,030 comparable items (median $54.99).
Specifications
| Product | |
|---|---|
| Brand name | Ideal |
| Product type | Assortments & Kits |
Questions about this item
How do I install the 61-176 adapter on a SureTest 61-164 or 61-165 circuit analyzer, and what step is often missed?
Plug the adapter cord into the analyzer's NEMA 5-20 receptacle and verify the isolated ground indicator lights; the step often missed is confirming the indicator before testing.
What maintenance or replacement will the 61-176 adapter need after extended use?
Inspect the polyethylene housing and cord for cracks or discoloration; replace the adapter if the isolated ground indicator fails to illuminate during a known-good circuit test.
What limit appears first when the 61-176 adapter is used continuously on a 20 A circuit?
The NEMA 5-20 rating limits continuous current to 20 A; exceeding this will trip the upstream breaker before the adapter itself fails.
More in Meters, Testers & Measuring Tools
Similar items
Jansicotek KW208 12V Battery Tester 100-2000 CCA
- Energy Star Qualifi…
- 5.98 × 3.39 × 1.77…
Jansicotek KW208 12 V 100-2000 CCA Battery Tester
- Energy Star Qualifi…
- 5.98 × 3.39 × 1.77…
GODIAG GT108 C Configuration OBDI-OBDII Conversion Adapter measurement tool
- Inch: 9.06 × 4.33 ×…
- Code Scanners & Acc…





