Iota
Iota ILBLP CP15 HE SD B M9 LED Emergency Driver ballast
Provides 90 minutes of emergency LED lighting at up to 15 W from 120 to 277 V AC
- Product typeBallasts
- 90 minutes emergency lighting when mains power fails
- 120-277V AC input suits most commercial installations
- 15 W maximum load supports single LED fixtures
- Low-profile steel housing fits tight ceiling voids
- CA Title 20 compliant for regulated markets
Emergency LED driver for single fixtures
The IOTA ILBLP CP15 HE SD B M9 provides 90 minutes of emergency illumination for one LED bulb up to 15 W. It accepts an input voltage range of 120 to 277 V AC and meets CA Title 20 compliance. This low-profile unit is intended for indoor lighting installations that require a compact backup solution.
Sustained output during extended outage
The driver maintains fixture-dependent lumens for the full 90 minute emergency duration rather than only a brief peak. Continuous operation at the rated 15 W maximum keeps light levels stable throughout the required period. Thermal management in the steel housing supports consistent performance without derating during the entire cycle.
Steel low-profile housing with simple mounting
A steel enclosure measuring 14 11/16 in length, 2 5/16 in width and 1 3/16 in height fits shallow plenums and tight ceiling voids. The low-profile form factor allows installation where taller ballasts would conflict with structure or insulation. Builders needing multiple bulbs per driver or longer run times will need a different unit.
How it compares
Measured against everything we stock in Lamp Ballasts & Drivers, at today’s prices. Recalculated every night.
- Price $206.99
- Pricier than about 90% of the 265 comparable items (median $61.99).
Specifications
| Product | |
|---|---|
| Brand name | IOTA |
| Product type | Ballasts |
Questions about this item
How much power does the ILBLP CP15 HE SD B M9 draw during continuous emergency operation?
The driver supports a maximum bulb load of 15 W and operates from a 120 to 277 V AC supply, so continuous draw will not exceed that lamp rating.
What existing fixture components are required for the ILBLP CP15 HE SD B M9 to function?
You need a compatible LED bulb up to 15 W and a fixture that can accommodate the driver’s 14 11/16 in length, 2 5/16 in width and 1 3/16 in height.
Will the ILBLP CP15 HE SD B M9 work with an older fluorescent ballast still wired in the same fixture?
This unit is an LED emergency driver only; it replaces the normal ballast for emergency operation and is not designed to share a fixture with a legacy fluorescent ballast.
More in Lamp Ballasts & Drivers
Similar items
Elemental LED DI-DM-24V100W-0-10V-LPS3R LO-PRO Wet Loc Jct Box Driver Combo 24V 100W ballast
- Ballasts
Elemental LED DI-TD-24V-96W-LPS3R LO-PRO Wet Loc Jct Box Driver Combo 24V
- Ballasts





