Legrand PS5369XHG Straight Blade Connector 5-20R 20A 125V AC
A hospital-grade straight-blade connector rated 20 A, 125 V AC with screw terminals for cable diameters from 0.23 in to 0.72 in
- Product typeStraight Blade Devices
- Hospital-grade durability for demanding commercial environments
- 20 A, 125 V AC rating supports heavy-duty equipment
- Screw terminals accept cables from .23 to .72 in diameter
- Chemical-resistant nylon housing withstands harsh conditions
- 2-pole, 3-wire NEMA 5-20R configuration ensures secure connections
Straight Blade Connector 5-20R 20A
This Legrand straight blade connector is a hospital-grade electrical device rated for 20 A at 125V AC. It features a 2-pole, 3-wire configuration with screw terminal connections and a nylon housing that resists chemicals.
Suited for commercial and medical-grade wiring
Electricians wiring hospital-grade receptacles or commercial circuits that require a NEMA 5-20R configuration will find this connector matches the specification. It is not for installers who need an IP-rated enclosure for wet locations, nor for circuits operating above the 125V AC single-phase rating.
20 A 125V AC NEMA 5-20R rating
The single specification that decides fit is the NEMA 5-20R rating of 20 A at 125V AC single phase. Only circuits designed for this exact configuration and voltage should use this connector.
How it compares
Measured against everything we stock in Electrical Enclosures & Cabinets, at today’s prices. Recalculated every night.
- Price $22.99
- Cheaper than about 66% of the 1,411 comparable items (median $39.99).
Specifications
| Product | |
|---|---|
| Brand name | Legrand |
| Product type | Straight Blade Devices |
Questions about this item
What cable diameter range does the Legrand PS5369XHG straight blade connector accept?
The connector fits cables from 0.23 in to 0.72 in outer diameter, covering the range needed for typical 20 A 125 V AC installations.
How do you terminate the wires on this 5-20R hospital-grade connector, and what is the common mistake?
Loosen the three screw terminals, insert each stripped conductor fully, then tighten securely; the step often missed is verifying no stray strands remain outside the terminal cage.
When should the nylon housing or screw terminals on this 20 A straight blade connector be inspected or replaced?
Inspect after any chemical exposure or if the housing shows cracking, discolouration, or the screw terminals no longer clamp the conductors firmly.
More in Electrical Enclosures & Cabinets
Similar items
Extreme Broadband Engineering IPE994-LTC 9x9x4 electrical box
- Enclosures
- Universal
Cheval Electronic Enclosure Co.,Ltd 3U 131 x 178 x 305 mm SLATE GREY electrical box
- Electrical Boxes
Bryant 8369T Straight Blade Connector 5-20R 20 A 125V AC 2 Pole 3 Wire
- Straight Blade Devi…
- 0.245 in to 0.655 in