Liebert PD2-104 PDU 60A 4×5-20R 2×L6-30R 2×L6-20R
Distributes power through eight mixed NEMA outlets from a 60 A hardwired input with maintenance bypass for GXT4 UPS units
- Product typeConsumer Electronics
- Key featuresProduct Name:PD2-104 8-Outlets PDU Output Receptacles:2 x NE
- Product weight6.6 lb (2.99 kg)
- Eight mixed outlets support diverse equipment
- 60 A hard-wire input feeds high-density racks
- Maintenance bypass enables hot-swap UPS service
- Designed for GXT4 8-10 kVA units
- Weighs 6.60 lb for easy mounting
Output distribution
This power distribution unit provides eight receptacles for connecting equipment to a Vertiv Liebert GXT4 8-10kVA UPS. It accepts a hardwired 60 A input and delivers power through four NEMA 5-20R, two NEMA L6-20R and two NEMA L6-30R outlets. The unit mounts in the rear of the UPS to convert the output wiring to a plug-and-play configuration.
Installers needing hot-swap UPS maintenance
The integrated maintenance bypass lets technicians remove or replace the UPS without cutting power to connected loads. Sites that require only hardwired output connections or a different receptacle mix should select an alternative POD model. Facilities without a compatible GXT4 8-10kVA UPS cannot use this unit.
60 A hardwired input rating
The PDU is rated for a 60 A, 4-wire (2PH+N+G) hardwire feed that matches the UPS input specification. This single electrical rating determines whether the unit can be safely installed on the available supply circuit.
How it compares
Measured against everything we stock in Rackmount PDUs, at today’s prices. Recalculated every night.
- Price $542.99
- Pricier than about 56% of the 643 comparable items (median $451.99).
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Specifications
| Product | |
|---|---|
| Brand name | Liebert |
| Model name | PD2-104 |
| Product type | Consumer Electronics |
| Size & build | |
| Product weight | 6.6 lb (2.99 kg) |
| Shipping weight | 4.08 kg |
| Package size | 520 × 310 × 220 mm |
Questions about this item
What maintenance does the PD2-104 bypass switch require over time?
The maintenance bypass enables hot-swapping the UPS without power interruption; the unit itself has no user-serviceable parts and needs no scheduled maintenance beyond standard electrical inspections.
Which receptacle rating reaches its limit first when the PD2-104 runs at full 60 A load?
The two NEMA L6-30R outlets are each rated for 30 A, so they hit their per-receptacle limit before the 20 A outlets or the overall 60 A feed.
How much heat and noise does the PD2-104 add when installed in a GXT4 UPS running continuously?
The PD2-104 is a passive distribution box with no fans or active components, so it adds no audible noise and negligible heat beyond normal conductor losses.
More in Rackmount PDUs
Similar items
CyberPower CPS1215RM 120V 15A Basic PDU 10 Outlets 15ft NEMA 5-15P 1U
- 1U
- 1U
Tripp Lite PDUMNV30HVLX 5.8kW Monitored PDU 20 C13 4 C19
- 200 V AC, 208 V AC,…
- 200 V AC, 208 V AC,…
Tripp Lite PDUMV20 Metered PDU 20A 28 Outlets 120V 15ft 0U Vertical
- 0U
- 120 V
Schneider Electric AP7802B Metered PDU 2U 30A 120V 16x NEMA 5-20R
- 2U
- CSA , FCC Part 15 C…