We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Liebert

Liebert PD2-106 PDU 8-Outlets 60A 4x L5-20R 4x L6-20R

SKU CH-20V3-CECSW MPN PD2-106

A 60 A power distribution unit with four NEMA L5-20R and four NEMA L6-20R outlets, hardwire three-wire-plus-ground input, weighing 6.60 lb

  • Product typeConsumer Electronics
  • Key featuresProduct Name:PD2-106 8-Outlets PDU Output Receptacles:4 x NE
  • Product weight6.6 lb (2.99 kg)
  • 8 outlets deliver flexible power distribution
  • 60 A rating supports high-density rack loads
  • Hardwire 4-wire input enables direct panel connection
  • Four L5-20R and four L6-20R receptacles mix voltages
  • 60 lb weight simplifies rack mounting

PDU for GXT4 8-10kVA UPS

The Liebert PD2-106 is a power distribution unit built for Vertiv GXT4 UPS models rated 8 to 10 kVA. It provides a maintenance bypass so connected equipment stays powered while the UPS is serviced. The unit accepts a hardwired 4-wire input and distributes power through eight locking receptacles. It suits data-centre and critical-infrastructure operators who need continuous uptime during UPS maintenance.

Installation and common issues

The PDU mounts in a standard rack and connects via a hardwire terminal block with three wires plus ground. A qualified electrician must terminate the 60 A feed to meet local code. The four NEMA L5-20R and four NEMA L6-20R outlets accept locking plugs that resist accidental disconnection. Mis-wiring the two-phase input or exceeding the 20 A per receptacle rating are the typical errors that cause nuisance tripping or overload.

60 A two-phase input rating

The single specification that decides fit is the 60 A, 4-wire (2PH+N+G) hardwire input. Your upstream breaker, wiring and UPS frame must all support this exact current and phase configuration. If the site supply is single-phase, three-phase or rated below 60 A, this PDU cannot be used. No other current or phase arrangement is compatible.

How it compares

Measured against everything we stock in Rackmount PDUs, at today’s prices. Recalculated every night.

Price $523.99
Pricier than about 55% of the 643 comparable items (median $451.99).

New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.

Specifications

Product
Brand nameLiebert
Model namePD2-106
Product typeConsumer Electronics
Size & build
Product weight6.6 lb (2.99 kg)
Shipping weight4.23 kg
Package size524 × 304 × 221 mm

Questions about this item

How do I confirm the PD2-106 is operating correctly after hardwiring the 60 A input?

Verify the unit powers on and each of the eight receptacles delivers voltage matching its NEMA rating; the maintenance bypass should transfer load to utility without interruption when engaged.

What ships with the PD2-106 and what must I source separately?

The PDU itself includes the hardwire terminal block for 3W + G input and eight output receptacles (four L5-20R, four L6-20R); input cable, conduit, breakers and mounting hardware are not supplied.

Should I choose the PD2-106 for a 10 kVA GXT4 UPS or is another capacity needed?

The PD2-106 is listed for GXT4 8-10 kVA models and provides 60 A through four L5-20R and four L6-20R outlets; match the UPS kVA rating to this range.