We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
Delivers 240 W at 42 V with up to 94 % efficiency, IP67/IP65 rating, active PFC and adjustable output for indoor or outdoor LED lighting
The NShi HLG-240H-42 delivers a constant 42V output at 5.72A with a 240W rating. Built-in active PFC and up to 94% efficiency suit LED lighting and street lighting installations. IP67 and IP65 rated enclosures allow indoor or outdoor mounting. Output current is adjustable via internal potentiometer on A-Type models.
This unit supersedes supplies lacking active power factor correction or surge immunity rated to 4kV under IEC61000-4-5. The jump is worth it when installations demand Class I Division 2 hazardous-location compliance or timer dimming functions. Multiple model variants cover adjustable voltage, 3-in-1 dimming and terminal-block wiring needs.
Verify the AC mains voltage does not exceed 305VAC and that the enclosure type matches the required IP rating. Confirm the load stays within the 240W limit and that wiring method suits the chosen A, B, C or Blank-Type variant. Ensure local regulations accept the 7-year warranty terms for the intended application.
Measured against everything we stock in Rackmount Server Cases, at today’s prices. Recalculated every night.
New to this? Buying PC parts with Monero — what to check, what it costs to pay, and what is never asked for.
| Size & build | |
|---|---|
| Chassis style | Desktop |
The HLG-240H-42 carries IP67 and IP65 ratings, making it suitable for outdoor installations where water and dust ingress protection are required.
Connecting the dimming control wires for the 3-in-1 function (1~10VDC, PWM signal, or resistance) is the step most often overlooked during installation.
Inspect the convection-cooled chassis annually and clean any accumulated dust to maintain the 94% efficiency rating and thermal performance over the 7-year design life.
More in Rackmount Server Cases
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?