Pintech PT-630 100MHz 3000V differential measurement tool
Measures differential signals up to 3000 V with 100 MHz bandwidth and 3.5 ns rise time
- Measurement accuracy±2%
- Certifications and standardsCE
- Size or dimensions187 × 83 × 41 mm
- Sold asEach
- Product typeElectrical Testing & Measuring
- 100 MHz bandwidth captures fast signals
- 5 ns rise time resolves rapid edges
- 3000 V differential range handles high-voltage circuits
- 50X and 500X attenuation ratios suit varied signal levels
- BNC interface connects to any oscilloscope
High-voltage differential probe for oscilloscopes
The PT-630 converts two-point signals to a ground-referenced output for oscilloscopes, meters or data-acquisition equipment. It handles up to 3000 V peak-to-peak at 500X attenuation and offers DC to 100 MHz bandwidth with a 3.5 ns rise time. Accuracy is ±2% and common-mode rejection reaches >80 dB at 60 Hz and >50 dB at 100 kHz.
Installing the probe and common issues
Connect the BNC cable to a 1 MΩ oscilloscope input and power the unit from the supplied adapter or internal battery. The 30 cm input leads and 90 cm BNC cable give reasonable reach but keep the 1500 V DC input limit in mind when probing motor-drive circuits. Exceeding the rated common-mode voltage of 1050 V RMS or using the wrong attenuation setting will damage the probe.
Bandwidth and attenuation limits
At 50X attenuation the bandwidth is DC-50 MHz with a 300 V peak-to-peak test voltage; at 500X it extends to DC-100 MHz with 3000 V peak-to-peak. The output impedance is 4 MΩ//1.18 pF single-ended and 8 MΩ//0.59 pF differential. The probe is not suited for signals faster than the stated rise time or for common-mode voltages above the specified RMS value.
How it compares
Measured against everything we stock in Meters, Testers & Measuring Tools, at today’s prices. Recalculated every night.
- Price $356.99
- Pricier than about 86% of the 3,030 comparable items (median $54.99).
Specifications
| Product | |
|---|---|
| Brand name | PINTECH |
| Model name | PT-630 |
| Product type | Electrical Testing & Measuring |
| Performance | |
| Measurement accuracy | ±2% |
| Size & build | |
| Size or dimensions | 187 × 83 × 41 mm |
| Environment & compliance | |
| Certifications and standards | CE |
Questions about this item
How do I verify the PT-630 is working correctly after connecting it to my oscilloscope?
Check that the BNC output shows a clean square wave with a 3.5 ns rise time at the 50X or 500X attenuation setting, and confirm the ±2 % accuracy on a known DC voltage source.
What accessories come with the PT-630 and what must I supply separately?
The box includes the PT-630 differential probe, one adapter, two probe hooks and a manual; you must provide an oscilloscope with a 1 MΩ BNC input and either the supplied adapter or a battery for power.
When should I use the 50X setting versus the 500X setting on the PT-630?
Use 50X for signals up to 300 V peak-to-peak with 50 MHz bandwidth; switch to 500X for signals up to 3000 V peak-to-peak with the full 100 MHz bandwidth.