Pintech PT-8110 differential probe 100MHz 100X/1000X 1400V measurement tool
Measures differential signals up to 1400 V with 100 MHz bandwidth and selectable 100X or 1000X attenuation
- Measurement accuracy±2%
- Certifications and standardsCE
- Size or dimensions187 × 83 × 41 mm
- Sold asEach
- Product typeElectrical Testing & Measuring
- Measures up to 1400 V peak-to-peak at 1000X attenuation
- 100 MHz bandwidth at 1000X for fast signal capture
- 5 ns rise time resolves rapid transients
- >80 dB CMRR at 60 Hz rejects common-mode noise
- BNC interface works with any oscilloscope input
High-voltage differential probe for oscilloscopes
The Pintech PT-8110 converts two-point signals to ground-referenced outputs for oscilloscopes, meters and data-acquisition gear. It covers DC to 100 MHz at 1000X attenuation and DC to 50 MHz at 100X attenuation with a 3.5 ns rise time. Typical accuracy is ±2%.
Thermals noise and power draw
The probe operates from the oscilloscope supply and adds no fan noise or significant heat to the bench. Input impedance is 8 MΩ // 0.59 pF differentially and 4 MΩ // 1.18 pF single-ended. Common-mode rejection exceeds 80 dB at 60 Hz and 50 dB at 100 kHz.
Bundled adapter and hooks
A BNC adapter connects the probe to any oscilloscope with a standard BNC input. Two probe hooks attach to component leads for hands-free measurement. The printed manual explains attenuation selection and voltage limits.
How it compares
Measured against everything we stock in Meters, Testers & Measuring Tools, at today’s prices. Recalculated every night.
- Price $608.99
- Pricier than about 90% of the 3,030 comparable items (median $54.99).
Specifications
| Product | |
|---|---|
| Brand name | PINTECH |
| Model name | PT-8110 |
| Product type | Electrical Testing & Measuring |
| Performance | |
| Measurement accuracy | ±2% |
| Size & build | |
| Size or dimensions | 187 × 83 × 41 mm |
| Environment & compliance | |
| Certifications and standards | CE |
Questions about this item
How do I connect the PT-8110 probe to my oscilloscope, and what setting do people forget?
Plug the BNC connector into any oscilloscope with a 1 M input impedance, then slide the switch to 100X or 1000X to match the expected voltage range; forgetting to match the attenuation setting is the common error.
Which parts of the PT-8110 will need replacement after extended use?
The two probe hooks and the supplied adapter are the only consumable accessories; the probe body itself has no user-replaceable modules.
At what voltage does the PT-8110 hit its measurement ceiling during long captures?
The common-mode RMS limit is 490 V, and the single-ended DC limits are 70 V at 100X or 700 V at 1000X; exceeding any of these first will clip the signal.
More in Meters, Testers & Measuring Tools
Similar items
InfiRay T3 Thermal Imager Camera for Android Phone with Holder
- Thermal Imager Came…
Fieldpiece DR82 infrared refrigerant leak detector measurement tool
- Test Equipment