Pomona Electronics 6244-48-0 Mini Hook Test Lead 48 In Black
A 48-inch black mini-hook test lead with an 18 AWG silicone-insulated wire, rated for 300 V CAT II and 5 A, featuring a moulded right-angle shrouded banana plug
- Product typeElectronic
- 48-inch reach for flexible bench access
- CAT II 300 V rating for safe low-voltage measurements
- Integral one-piece moulded plug for durable connection
- Right-angle shrouded banana plug fits standard meter jacks
- Silicone-insulated 18 AWG wire handles up to 5 A current
Mini hook test lead 48 In Black
This mini hook test lead is a single 48-inch black cable designed for technicians and hobbyists who need a secure hook connection to component leads or test points. It plugs into any multimeter, clamp meter or test instrument that accepts a standard shrouded banana plug.
Integral moulded plug and double-crimped wire
The plug is moulded directly to the silicone-insulated 18 AWG wire in a one-piece design, and the conductor is double crimped for a long-lasting connection. These construction details reduce the chance of intermittent contact or cable pull-out during repeated use.
CAT II 300 V rating with right-angle shrouded plug
The lead carries a CAT II 300 V safety rating and a maximum current of 5 A, making it suitable for low-energy measurement circuits. The right-angle shrouded plug keeps the connection compact at the instrument while maintaining the protective shroud.
How it compares
Measured against everything we stock in Meters, Testers & Measuring Tools, at today’s prices. Recalculated every night.
- Price $13.99
- Cheaper than about 86% of the 3,030 comparable items (median $54.99).
Specifications
| Product | |
|---|---|
| Brand name | POMONA |
| Product type | Electronic |
Questions about this item
How often should the 18 AWG silicone wire be inspected for wear?
Check the wire and mini-hook tip before each session; replace the lead if the insulation shows cuts, the crimps loosen or the hook no longer grips securely.
What is the first limit reached during continuous use?
The 5 A current rating is the limiting factor; sustained loads above 5 A will overheat the 18 AWG conductor before the 300 V CAT II voltage ceiling becomes an issue.
Does the lead get warm or stiff when left connected all day?
At or below 5 A the 18 AWG silicone wire stays cool and remains flexible; noticeable heating only occurs if the current limit is exceeded.
More in Meters, Testers & Measuring Tools
Similar items
Dr.meter Fish Scale 110lb/50kg Backlit LCD with Measuring Tape
- FDA Class VI Seats





