Red Hat 8215B050CSA 120V AC Aluminum Solenoid Valve Trap
Controls air and fuel gas flow with a normally closed, high-flow aluminum valve rated for 25 psi differential pressure
- Product typeDrain Components
- Main materialHAWA
- High Cv 21 delivers strong flow capacity
- Normally closed design prevents unintended media passage
- Aluminium body resists corrosion in air and fuel gas lines
- 120 V AC coil suits standard mains supply
- Rated for 25 psi maximum differential pressure
Valve for air and fuel gas
The Red Hat 8215B050CSA is a normally closed, two-way solenoid valve designed for air and inert gas or fuel gas service. It accepts 110V AC or 120V AC supply and fits a one-inch nominal pipe connection. The aluminium body houses a 1 5/8 inch orifice with an NBR seal for reliable shut-off.
Sustained flow performance
With a coefficient of volume of 21, the valve delivers high flow capacity during continuous operation. The maximum operating pressure differential for air or inert gas is rated at 25 psi, providing stable control under steady demand. Fuel gas and fuel oil pressure differentials are not applicable for this model.
Aluminium body and mounting
The aluminium construction resists corrosion in typical plumbing environments while keeping the assembly lightweight. The one-inch pipe size aligns with standard fittings, simplifying installation in existing lines. A Proposition 65 notice applies for California buyers regarding reproductive-harm chemicals.
How it compares
Measured against everything we stock in Drain Stoppers, Strainers & Traps, at today’s prices. Recalculated every night.
- Price $429.99
- Pricier than about 90% of the 4,240 comparable items (median $31.99).
Specifications
| Product | |
|---|---|
| Brand name | Red Hat |
| Model name | 8215B050CSA |
| Product type | Drain Components |
| Size & build | |
| Main material | HAWA |
Questions about this item
How much heat does the coil generate when the valve stays energised all day?
The coil is rated for 120 V AC operation; continuous duty is within design limits and no external cooling is required.
What piping and electrical supplies must be on site before installation?
You need a 1 in nominal pipe connection, compatible thread sealant, and a 110–120 V AC power source with a suitable conduit.
Will the NBR seals hold up if the line still carries older fuel-oil residue?
The valve is rated for air and inert gas only; fuel-oil service is not applicable, so residue exposure should be avoided.
More in Drain Stoppers, Strainers & Traps
Similar items
Wheeler-Rex 13970 Rising Stem Hand Wheel Adapter
- Drain Components
Red Hat JB8214250CSA Solenoid Valve 2-Way 1in 110/120V AC
- Drain Components
Banjo RB300-150 3 inch MNPT x 1-1/2 inch FNPT Reducing Bushing Schedule 80 trap
Zoeller BN2057 1/3 HP 115V Submersible Sump Pump Trap
- Drain Components
- Cast Iron